3
Figure 2.10
2.7
Connecting Power
The RUGGEDCOM RX1400 supports a single integrated high AC/DC or low DC power
supply.
Note
Before installing the device, note the following:
•
•
•
2.7.1
Connecting High AC/DC Power
To connect a high AC/DC power supply to the device, do the following:
Electrical hazard – risk of damage to equipment
Do not connect AC power cables to terminals for DC power. Damage to the power
supply may occur.
RUGGEDCOM RX1400
Installation Manual, 01/2021, C79000-G8976-1103-17
Normally Open
Failsafe Alarm Relay Wiring
An appropriately rated AC or DC circuit breaker must be installed.
Use minimum #16 gage copper wiring when connecting terminal blocks.
Equipment must be installed according to applicable local wiring codes and
standards.
NOTICE
Installing the Device
2.7 Connecting Power
25