Connecting Power - Siemens RUGGEDCOM RSG2100 Installation Manual

Hide thumbs Also See for RUGGEDCOM RSG2100:
Table of Contents

Advertisement

RUGGEDCOM RSG2100
Installation Guide
1
1
Figure 4: Panel Mounting
1. Screw
2. Panel/DIN Rail Adapter
2.
Install the supplied screws to secure the adapters to the panel.
Section 2.2

Connecting Power

The RUGGEDCOM RSG2100 supports a single or dual redundant AC and/or DC power supplies. The use of two
power modules is recommended to provide redundancy and load balancing.
The RUGGEDCOM RSG2100 can be equipped with either a screw-type or pluggable terminal block, which
provides power to both power supplies. The screw-type terminal block is installed using Phillips screws and
compression plates, allowing either bare wire connections or crimped terminal lugs. Use #6 size ring lugs for
secure, reliable connections under severe shock or vibration.
CAUTION!
Electrical hazard – risk of damage to the device. Disconnect the device from the power supply if power
input is above or below the specified input range. For more information, refer to
Supply
Specifications".
NOTE
• For maximum redundancy in a dual power supply configuration, use two independent power
sources.
Connecting Power
Chapter 2
Installing Device
2
Section 4.1, "Power
9

Advertisement