Test
IEC 61000-4-18
Damped Oscillatory Wave
IEC 61000-4-29
IEC 60255-5
a
Siemens-specified severity levels
EMC Immunity Type Tests per IEEE 1613
Note
The RUGGEDCOM RX1400 meets Class 1 requirements for copper ports, which allows
for temporary communication loss.
Test
IEEE 1613
Fast Transient (SWC)
IEEE 1613.1/
IEC 61000-4-10
Environmental Type Tests
Test
IEC 60068-2-1
IEC 60068-2-2
RUGGEDCOM RX1400
Installation Manual, 01/2021, C79000-G8976-1103-17
Description
Voltage Dips
and Interrupts
Dielectric Strength
HV Impulse
Description
HV Impulse
Dielectric Strength
Oscillatory (SWC)
Radiated RFI
ESD
Damped Oscillating
Magnetic Field
Description
Cold Temperature
Cold Storage
Dry Heat
Dry Heat Storage
6.2 EMC and Environmental Type Tests
Slow Damped
DC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
Signal Ports
DC Power Ports
Signal Ports
DC Power Ports
Signal Ports
DC Power Ports
Earth Ground Ports
Signal Ports
DC Power Ports
Enclosure ports
Enclosure Contact
Enclosure Air
Enclosure Ports
Test Ad
Test Ab
Test Bd
Test Bb
Certification
Test Levels
2.5 kV Common
100 kHz or 1 MHz
30% for 0.1 s
60% for 0.1 s
100% for 0.05 s
2 kV
5 kV
Test Levels
5 kV
2828 VDC or 2 kV
± 4 kV @ 2.5 kHz, 5 kHz
2.5 kV Common mode @1 MHz
2.5 kV Common Mode
1 kV Differential Mode @ 1 MHz
35 V/m
± 8 kV
± 15 kV
100 A/m for 1 s (100 kHz and 1 MHz)
Test Levels
-40 °C (-40 °F), 16 Hours
-40 °C (-40 °F), 16 hours
85 °C (185 °F), 16 Hours
85 °C (185 °F), 16 hours
Severity
Levels
3
 
 