5. Press button "7" to enter Offset Limits Mode
6. Using digital calipers, measure one of the folded pieces of paper as shown in Figure 29 and record
these measurements.
It is very important to make all Offset measurements using either dial or digital calipers. A
line gage, pica stick, ruler, tape measure, etc., is not accurate enough. Typical Fold Table offset
values are between 2.20 and 2.45 inches. If your measurement is outside of this range, contact
Martin Yale Technical Support for assistance.

7.8.2 Fold Table #1 Home

To set the home offset position for Fold Table #1, do the following;
1. Press the Fold Table #1 button. The display will look like the example below (Figure 30).
2. Using the number pad, enter the value that was measured in section 7.8.1 (see Figure 29 – 1st
Fold) and press "Enter" when done.

7.8.3 Fold Table #2 Home

To set the home offset position for Fold Table #2, do the following;
1. Press the Fold Table #2 button. The display will look like the example below (Figure 31).
2. Using the number pad, enter the value that was measured in section 7.8.1 (see Figure 29 – 2nd
Fold) and press "Enter" when done.

7.8.4 Diverter Offset

This is a continuation of Fold Table #2 Home. To change this value, you must follow the directions
starting at section 7.8.3 - Fold Table #2 Home. The Diverter Offset value tells the folder how far Fold
Table #2 must move inward to engage the Paper Diverter to perform a half fold.
The folder will then ask/show the distance that the fold table must be driven to engage the paper
diverter. The default value for this setting is .43 inches. To change this value, use the keypad to enter
a new value and press "Enter" to save.
The Diverter Offset value does not normally need to be changed for any reason, except when
there are problems performing a Half fold, or the fold table is making a loud clicking noise when
moving into Half fold. Improperly setting this value can cause damage to the fold table.
value should ONLY be changed as a last resort!
Revision 3.0
Fold Tbl 1 Home Pos.
Len.=[X.XX]: .
Fold Tbl 2 Home Pos.
Len.=[X.XX]: .
Diverter Offset
Len.=[.XX]: .
Martin Yale Industries, Wabash, Indiana, USA 260-563-0641