CHAPTER 7 Managing Phones with the Device Manager
Actions that go beyond the devices' periodic provisioning cycle will be supported in next
releases. The Check Status option is irrelevant for Android-based Teams devices therefore it's
omitted from the 'Actions' menu.
●
●
Configuring a Periodic Provisioning Cycle
Network administrators can configure how often periodic provisioning cycles will occur, to suit
enterprise management preference.
➢ To configure how often periodic provisioning cycles will occur:
■
Use the following table as reference.
Parameter
provisioning/period/type Defines the frequency of the periodic provisioning cycle. Valid
Configuring TimeZone and Daylight Savings
Network administrators can configure TimeZone and Daylight Savings to suit enterprise
requirements.
➢ To configure TimeZone and Daylight Savings:
■
Use the following table as reference.
To change a device's configuration, see the Device Manager Administrator's
Manual. Changing a device's configuration using the Device Manager is the same
for Android-based Teams devices as for UC devices.
To commit a change made at the template/tenant/site/group/user level, perform
Generate Configuration. The change can be validated in the device's .cfg file.
The Android-based endpoint pulls the updated configuration when the next periodic
provisioning cycle occurs.
Table 7-2: Periodic Provisioning Cycle
values are:
■
HOURLY
■
DAILY (default)
■
WEEKLY
■
POWERUP
■
EVERY5MIN
■
EVERY15MIN
Each value type is accompanied by additional parameters (see
Supported Parameters on the next page ) that further defines
the selected frequency.
C470HD | Users & Administrator's Manual
Description
- 67 -