3

temperature input ranges

The table below shows the temperature input ranges of the ems55 series controllers for each sensor type.
sensor
appliance sensor
condenser sensor
evaporator sensor
Note:
The NTC (negative temperature coefficient) thermistor from elstat is rated at:
l
º
º
º
-35
C to 125
C (-31
F to 257
3.1

how to mount the appliance sensor

The appliance sensor measures air temperature of the refrigerated compartment by measuring the return air temperature.
The diagram below shows the recommended position of the appliance sensor. The appliance sensor measures the air tem-
perature after the air has been drawn over the products. The return air provides a close approximation of the product tem-
perature.
To measure the return air temperature, secure the sensor to allow air to flow over the sensor head.
The sensor head should be placed at a right-angle to the air flow and secured using a P-clip.
The sensor head should not be completely covered by the P-clip or the sensor will not function correctly.
o
input range (
C)
º
º
-10
C to 23.3
C
º
+/- 0.5
C
º
o
50
C to 125
C
º
+/- 5.0
C
º
º
-30
C to 15
C
º
+/- 0.5
C
º
F).
o
input range (
F)
º
º
14
F to 74
F
º
+/- 1
F
º
º
122
F to 257
F
º
+/- 10
F
º
º
-22
F to 59
F
º
+/- 1
F
ems55advanced and ems55Radvanced / General Use
13 of 84

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ems55advanced and is the answer not in the manual?

Questions and answers

Marcilene de Almeida Ferreira
February 5, 2025

O meu aparelho está desregulado.....como colocar os números q vieram de fábrica nele

This manual is also suitable for:

Ems55radvancedEms25+Ems25advanced

Table of Contents

Save PDF