Maximum Defrost On Demand Time (Dto); Freeze-Up Protection (Dtt) - Elstat ems55advanced Manual

Hide thumbs Also See for ems55advanced:
Table of Contents

Advertisement

display
Provides the option to end a defrost cycle as follows:
on the defrost duration (
l
on defrost duration (
l
description
(
If the defrost termination method (dtF) is set to use the defrost duration (dd) or the defrost termination
temperature (dtd), the ems controller ends the defrost cycle on the first to occur.
Defrost method (dF) must be set to 0
considerations
Used only with sub zero and OFC firmware.
Not available on GDC firmware.
range
00 (time[dd]) or 01 (time[dd] or temperature[dtd])
global default
01 (time or temperature)
10.22

Maximum defrost on demand time (dtO)

The table below details the maximum defrost on demand time (dtO) parameter.
Display
Maximum defrost on demand time is the maximum time of a temperature based
Description
defrost cycle.
Available only with the ems55 series using OFC (Open Front Cooler) firmware.
Considerations
This parameter may not appear in all firmware versions.
Range
10 to 120 minutes
Global default
30 minutes
10.23

freeze-up protection (dtt)

The table below details the freeze-up protection (dtt) parameter.
display
description
Defines the temperature to stop further cooling to prevent freeze-up due to low temperature.
considerations Must be set below the set point (S P) temperature.
range
-15 to 10ºC (5 to 50ºF)
0.0ºC (32ºF)
global default
ems75sz: -6.0°C (21°F)
dd
) only
dd
) or defrost termination temperature
dtd
).
ems55advanced and ems55Radvanced / General Use
74 of 84

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ems55advanced and is the answer not in the manual?

Questions and answers

Marcilene de Almeida Ferreira
February 5, 2025

O meu aparelho está desregulado.....como colocar os números q vieram de fábrica nele

This manual is also suitable for:

Ems55radvancedEms25+Ems25advanced

Table of Contents

Save PDF