10.24
fan cycle off (FCF)
The table below details the fan cycle off (FC F) parameter.
display
description
Defines the inactive period of the evaporator fan while the compressor is switched off.
Fan cycle is the fan cycle on (FC O) time + the fan cycle off (FC F) time.
considerations
Not used on the ems25
range
1 to 30 minutes
1 minute
global default
ems75sz: 20 minutes
10.25
fan cycle on (FCO)
The table below details the fan cycle on (FC O) parameter.
display
description
Defines the active period of the evaporator fan while the compressor is switched off.
Fan cycle is the fan cycle on (FC O) time + the fan cycle off (FC F) time.
considerations
Not used on the ems25
range
1 to 30 minutes
30 minutes
global default
ems75sz: 5 minutes
10.26
fan set point (FSP)
The table below details the fan set point (FS P) parameter.
display
Prevents excessive condensation on the evaporator in environments where warm, and presumed
humid, air is present by operating the evaporator fan.
description
If the fan set point (FS P) temperature is exceeded, the evaporator fan running continuously even if the
door is opened.
On reaching set point (S P) temperature, the evaporator fan switches off during door openings.
Not related to fan cycle on (FC O) or fan cycle off (FC F).
considerations
Not used with OFC firmware or the ems25
range
01 to 30ºC (33 to 86ºF)
global default
15ºC (59ºF)
ems55advanced and ems55Radvanced / General Use
75 of 84
+
+
+