3 TECHNICAL DATA

3
TECHNICAL DATA
Robust Feed U6 and Robust Feed Pulse, Valid from serial no. 014-xxx-xxxx
Power Supply voltage
Power requirement
Rated supply current I
Settings data:
Wire feed speed
Torch connection
Max. diameter wire bobbin
Wire dimension:
Fe
Ss
Al
Cored wire
Weight
Maximum weight wire spool
Dimensions (l×w×h)
Operating temperature
Transport and storage temperature
Shielding gas
Maximum gas pressure
2)
Coolant
Maximum coolant pressure
Permissible load at +40 °C:
35% duty cycle
60% duty cycle
100% duty cycle
Permissible load at +55 °C:
35% duty cycle
60% duty cycle
100% duty cycle
Enclosure class
1)
Maximum speed is guaranteed on the whole speed range for all wires. For 2.0 mm solid
and 2.4 mm cored wire, speed is guaranteed in the speed range 0.8–8.0 m/min
(32–315 in./min). The Robust Feed U6 and Robust Feed Pulse will be able to achieve
higher feeding speed above the 8.0 m/min (315 in./min) but with higher tolerances.
2)
For "Robust Feed U6, Offshore, Water", "Robust Feed U6, Offshore, Water, Push Pull",
"Robust Feed Pulse, Offshore, Water" and "Robust Feed Pulse, Offshore, Water, Push
Pull")
0446 253 101
1
- 10 -
42 V AC, 50–60 Hz
181 VA
4.3 A
0.8–25.0 m/min (32–984 in./min)
EURO, Tweco 4
300 mm (12 in.)
0.6–2.0 mm (0.023–5/64 in.)
0.6–1.6 mm (0.023–1/16 in.)
0.8–1.6 mm (0.031–1/16 in.)
0.9–2.4 mm (0.035–3/32 in.)
16.7–18.5 kg (36.8–40.8 lb.)
20.0 kg (44.1 lb.)
675×265×418 mm (26.6×10.4×16.5 in.)
-20 to +55 °C (-4 to +131 °F)
-40 to +80 °C (-40 to +176 °F)
All types intended for MIG/MAG welding
5 bar (0.5 Mpa)
ESAB's ready mixed coolant
5 bar (0.5 Mpa)
630 A
500 A
400 A
600 A
450 A
350 A
IP44
© ESAB AB 2020