Fujitsu SPARC M12-1 Installation Manual page 129

Hide thumbs Also See for SPARC M12-1:
Table of Contents

Advertisement

PSB: PSB number
Test: Initial diagnosis status of the PSB
Unmount: The PSB cannot be recognized because it is not mounted or has failed.
Unknown: The PSB has not been diagnosed.
Testing: The initial diagnosis is in progress.
Passed: The initial diagnosis ended normally.
Failed: A failure occurred in the initial diagnosis.
Fault: The physical system board (PSB) is in a degraded state.
Normal: The PSB is normal.
Degraded: The physical system board (PSB) can operate but has a degraded
component.
Faulted: The physical system board (PSB) is not operating because a failure
occurred or it cannot be controlled because of a communication failure.
Example: SPARC M12-1 execution example (normal end), including execution of
show-devs and probe-scsi-all
XSCF> testsb -v -p -s -a -y
Initial diagnosis is about to start, Continue?[y|n] : y
PSB power on sequence started.
POST Sequence 01 Banner
:
<< Displayed execution results of "probe-scsi-all" >>
/pci@8100/pci@4/pci@0/pci@0/scsi@0
FCode Version 1.00.56, MPT Version 2.00, Firmware Version 20.00.10.00
Target a
Unit 0
Disk
SASDeviceName 500003970830ddd9
Target b
Unit 0
Disk
SASDeviceName 50000393b81b0fd8
:
<< Displayed execution results of "show-devs" >>
:
/pci@8300/pci@4/pci@0/pci@1
/pci@8300/pci@4/pci@0/pci@1/pci@0
/pci@8300/pci@4/pci@0/pci@1/pci@0/pci@0
/pci@8300/pci@4/pci@0/pci@1/pci@0/pci@0/pci@0
/pci@8300/pci@4/pci@0/pci@1/pci@0/pci@0/pci@0/pci@1
/pci@8300/pci@4/pci@0/pci@1/pci@0/pci@0/pci@0/pci@1/pci@0
/pci@8300/pci@4/pci@0/pci@1/pci@0/pci@0/pci@0/pci@1/pci@0/pci@11
/pci@8300/pci@4/pci@0/pci@1/pci@0/pci@0/pci@0/pci@1/pci@0/pci@10
/pci@8300/pci@4/pci@0/pci@1/pci@0/pci@0/pci@0/pci@1/pci@0/pci@8
/pci@8300/pci@4/pci@0/pci@1/pci@0/pci@0/pci@0/pci@1/pci@0/pci@1
/pci@8300/pci@4/pci@0/pci@1/pci@0/pci@0/pci@0/pci@1/pci@0/pci@0
/pci@8300/pci@4/pci@0/pci@1/pci@0/pci@0/pci@0/pci@1/pci@0/pci@11/pci@0
/pci@8300/pci@4/pci@0/pci@1/pci@0/pci@0/pci@0/pci@1/pci@0/pci@11/pci@0/pci@11
/pci@8300/pci@4/pci@0/pci@1/pci@0/pci@0/pci@0/pci@1/pci@0/pci@11/pci@0/pci@10
/pci@8300/pci@4/pci@0/pci@1/pci@0/pci@0/pci@0/pci@1/pci@0/pci@11/pci@0/pci@1
/pci@8300/pci@4/pci@0/pci@1/pci@0/pci@0/pci@0/pci@1/pci@0/pci@11/pci@0/pci@0
/pci@8300/pci@4/pci@0/pci@1/pci@0/pci@0/pci@0/pci@1/pci@0/pci@10/pci@0
TOSHIBA
AL13SEB600AL14SE 3702
SASAddress 500003970830ddda
TOSHIBA
MBF2300RC
SASAddress 50000393b81b0fda
1172123568 Blocks, 600 GB
3706
585937500 Blocks, 300 GB
Appendix A Troubleshooting
PhyNum 0
PhyNum 1
119

Advertisement

Table of Contents
loading

Table of Contents