Installation Without Optitap; Figure 4-8. Fiber Installation Without Optitap - ADTRAN Total Access 300 Series Installation And Maintenance Manual

Single family unit ont
Hide thumbs Also See for Total Access 300 Series:
Table of Contents

Advertisement

Total Access 300 Series Single Family Unit ONT Installation and Maintenance Guide

Installation without OptiTap

For the Splice Housing (P/N 1187770G1) the Fiber may be routed through the same opening
as the OptiTap. Use
Electronics Module.
1. Route the Incoming Fiber through the opening in the ONT Bracket Housing as shown
Optical Connector on
Electronics Module
2. Remove the end caps from the Bulkhead Connector. Retain these for future use.
3. Clean all optical surfaces before and after splicing.
4. Splice an SC/APC Fiber Connector to the end of the Incoming Fiber using a Fusion
5. Route any excess fiber using the Fiber Splice Tray.
6. Using the Fiber Jumper supplied with the Electronics Module, connect the
NOTE
Ensure the fiber cable is routed using the provided molded clamps on the
Electronics module.
4-14
Figure 4-8
below.
To/From
Electronics Module
Connector
Incoming Fiber

Figure 4-8. Fiber Installation without OptiTap

Splice, and connect it to the SPLICE IN side of the Bulkhead Connector.
ELECTRONICS IN connector on the Bulkhead Connector to the Optical Connector on
the bottom of the Electronics Module.
and the following instructions, to connect Fiber to the
To/From
Bulkhead Connector
Splice Tray
Splice In
Bulkhead
Connector