Total Access 362R Single Family Unit with RF Return Installation and Maintenance Guide

Fiber Drop Cable Route

!
WARNING
Do not look into the ends of optical fibers. Exposure to invisible LASER
radiation may cause serious retinal damage or even blindness. Verify the
optical source is disabled through the use of an optical power meter before
handling optical fibers.
!
CAUTION
Use caution when routing wires and cables. Avoid severe bending and
routing over sharp edges. Use grommet material when possible to avoid wear
on cable insulation.
The Outer Enclosure offers several alternatives for Fiber installation. These include:
• Corning Optitap
• Pre‐terminated Drop cable
• Drop cable and Field splice or Field termination
22
connection (refer to Figure 10) 
TM
 
Protective
Cap
OptiTap
Connector

Figure 10. Optitap Adapter Installation

Protective
Cover with
Lanyard
61187715G1-5B