Total Access 300 Series Single Family Unit ONT Installation and Maintenance Guide
8. Route the 6 AWG ground wire by the shortest and most direct route to the AC power
9. Attach the 6 AWG ground wire to the side of the subscriber premises with stainless steel
10. Clean the MGN connector with emery cloth to insure a stable connection.
11. Coat the connection with a metal corrosion preventative.
12. Connect the ground wire to the ground lug and tighten.
13. Attach a Warning Ground Tag to this grounding connection.
3-22
Splice Housing

Figure 3-14. ONT Ground Connection

ground system (MGN) of the customer premises (free of any sharp bends). (See the
"Alternative Grounding Method"
half moon clamps or tie-wrap the ground to the riser conduit of the buried fiber cable
drop. When using tie-wraps wait until the LPS wire run has been installed and tie-wrap
both the 6 AWG ground wire and the LPS wire run to the riser conduit of the Buried
Fiber drop.
on the following page if MGN is not available.)
OptiTap Housing
612877GONT-5C