Safety And Regulatory Compliance - ADTRAN Total Access 300 Series Installation And Maintenance Manual

Single family unit ont
Hide thumbs Also See for Total Access 300 Series:
Table of Contents

Advertisement

Safety and Regulatory Compliance

For the Safety and Regulatory Compliance Notice specific to an individual ONT, refer to the
"Related Online Documents and Resources"
!
WARNING
■ Read all warnings and cautions before installing or servicing this
equipment.
■ The protective earth (PE) grounding wire for this product must be 6 AWG
(13.3 mm
used in conjunction with an anti-rotation device. The connector must be a
suitable approved ground wire connector.
■ The Coaxial output of the Total Access 300 Series Single Family Unit ONT
is intended to be connected to the dwelling coaxial distribution system.
Verify the coaxial distribution system is separately grounded. Grounding
of the dwelling coaxial infrastructure shall use Listed grounding devices
(such as a grounding block) and must be installed in accordance with
Article 800 of the National Electric Code, ANSI/NFPA 70 and the authority
having jurisdiction, following the manufactures instructions.
C
CAUTION
This product uses a Class 1 Laser module that complies with 21 CFR 1040.10
and 1040.11 and IEC 60825-1 and -2. For continued compliance with the above
standards, install only ADTRAN-approved Class 1 Laser Modules in this
p r o d u c t . F o r a l i s t o a A D T R A N - a p p r o v e d S F P s a n d X F P s , s e e
adtran.com>support>support community>search SFP/XFP. ADTRAN
cannot certify system integrity with other laser modules.
!
CAUTION
612877GONT-5C
2
) copper and utilize either a two-hole or a one-hole lug that is
Risk of Electrical Shock
C A U T I O N !
C A U T I O N
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
section in the "Introduction".
4-3