Pr27 - Upper/Lower Limits; Pr28 - Lower Limit; Pr29 - Upper Limit; Pr30 - Offset Addition - Accurate Technology ProScale 950 Series Operation

Lcd readouts with firmware version 3.1 and higher
Hide thumbs Also See for ProScale 950 Series:
Table of Contents

Advertisement

Pr27 – Upper/Lower Limits ····················································· [0 or 1]
This parameter Enables/Disables the use of the
(Set Pr 28 to the lower limit & Pr 29 to the upper limit).
Default Value = 0
Pr 27 Setting
Pr28 – Lower Limit ··············· [0 to ± 999.999in] or [0 to ± 9999.99mm]
This value sets the lower limit of Upper/Lower Limits function when Pr27 = 1.
Default Value = 0.000
Pr29 – Upper Limit ··············· [0 to ± 999.999in] or [0 to ± 9999.99mm]
This value sets the upper limit of Upper/Lower Limits function when Pr27 = 1.
Default Value = 5.000 in. (127.00mm)
Pr30 – Offset Addition ·························································· [0 to 4]
This parameter Enables/Disables the use of the
Pr31, Pr32, Pr33, and Pr34 set the value of the offsets to be added.
Default Value = 0
Pr31 – Offset 1 ···················· [0 to ± 999.999in] or [0 to ± 9999.99mm]
This value is added to the current measurement (or position) when:
Pr 30  0, and
1
Default Value = .500 in. (12.7mm)
Pr32 – Offset 2 ···················· [0 to ± 999.999in] or [0 to ± 9999.99mm]
This value is added to the current measurement (or position) when:
Pr 30  0, and
2
Default Value = 2 in. (50.8mm)
Pr33 – Offset 3 ···················· [0 to ± 999.999in] or [0 to ± 9999.99mm]
This value is added to the current measurement (or position) when:
Pr 30  0, and
3
Default Value = 3 in. (76.2mm)
Pr34 – Offset 4 ···················· [0 to ± 999.999in] or [0 to ± 9999.99mm]
This value is added to the current measurement (or position) when:
Pr 30  0, and
4
Default Value = 3 in. (76.2mm)
Manual Part # 800-1402-002 Rev K, 072418
0
1
Pr30 Setting
0
1
2
3
4
is displayed in the upper left area of the LCD.
is displayed in the upper left area of the LCD.
is displayed in the upper left area of the LCD.
is displayed in the upper left area of the LCD.
Upper/Lower Limits
Upper/Lower Limits Function
Function DISABLED
Function ACTIVE
Offset Addition
Offsets Enabled
Offset 1 Enabled
Offsets 1 & 2 Enabled
Offsets 1, 2 & 3 Enabled
Offsets 1, 2, 3 & 4 Enabled
Function.
function.
None