Send

The Readout has an output port that may be used to send
measurement or position information to another device (i.e. a PC)
via a wireless transmitter or wired data converter.
See
Section 6: Accessories
After connecting a transmitter or cable to the 10 pin output connector on the
Readout, the user may initiate the data transmission by momentarily pressing
key. This will cause Snd to display on the Readout for 1 second to
the
SEND
show activation of the send function (even if no device is attached to the
Readout).
All inch modes are transmitted as decimal inches. All metric modes are
transmitted as millimeters. The position data transmitted is typically the
displayed position on the LCD, with the exception of when Special Function
Mode is set to Measurement Accumulation or Statistics modes (See
Readout
Functions). In those modes, the displayed (or calculated) values are
sent, NOT the current encoder position.
The data format and connector style of the output port is Mitutoyo Digimatic.
This is an industry standard that can be interfaced with most products including
multiplexers & RS232 converters (See
NOTE: When using a Wired Data Converter with Model 150 or 250
systems, Scales and Encoders with part numbers ending in 'G' should
always be used.

Offset Addition

Offset addition allows values to be pre-programmed that are then added to the
measurement, and the sum is displayed on the LCD. This function allows the
user to switch from one reference point to another.
See P
ROGRAMMING
The General Purpose and 950 Series Readouts support up to 4 user definable
offsets that may be added to the ABS position.
P
P
ROGRAMMING
ARAMETER
P
P
ROGRAMMING
ARAMETERS
When enabled, the user can scroll through the active offsets by
pressing the
F1
displayed on the upper left part of the LCD with each press of
When no numbers are displayed, no offset addition is active.
When the number 1 is displayed in the upper left corner, Offset
Addition Preset # 1 (
and the result is now displayed on the LCD.
Similarly, when the number 2 is displayed in the upper left corner, Offset
Addition Preset # 2 (
3 is displayed, Offset Addition Preset 3 (
measurement, and when the number 4 is displayed, Offset Addition Preset 4
(
) has been applied to the measurement and the result displayed.
Pr34
Manual Part # 800-1402-002 Rev K, 072418
P
(Pr30, 31, 32, 33 & 34)
ARAMETERS
enables or disables this function.
Pr30
Pr31, 32, 33 & 34
key. The numbers 1, 2, 3 or 4 will be
) has been applied to the measurement
Pr31
) has applied to the measurement. When the number
P
32
R
Section 6:
Accessories).
are used to configure this function.
) has been applied to the
Pr33