Measurement Accumulator - Accurate Technology ProScale 950 Series Operation

Lcd readouts with firmware version 3.1 and higher
Hide thumbs Also See for ProScale 950 Series:
Table of Contents

Advertisement

Measurement Accumulator

This Function allows multiple measurements to be made, and
the sum displayed on the Readout.
S
P
ET
ROGRAMMING
P
P
ROGRAMMING
ARAMETER
F3 & F4 are used to execute this function.
1. Press the
F4
The LCD will display Accu for 1 second followed by the total accumulated
measurements. The display format for the accumulated total is controlled
by both the currently selected measurement mode (
Programming Parameter
a.
If
Pr25
fractions), the accumulated total is displayed in Decimal Inches.
b.
If
Pr25
the accumulated total is displayed in mm.
c.
If
Pr25
modes, (decimal or fractions), the accumulated total is displayed as
feet and inches. (fff ii) where f=feet and i = inches
d.
If
Pr25
mode, (mm or cm), the accumulated total is displayed as meters
and millimeters. (MM mmm) where M=meters and m=millimeters.
2. Press the
F3
The LCD will display CLr for 1 second. The DRO will return to the normal
measuring mode.
3. To add a measurement to the accumulator, make the measurement and
then press the
the measurement has been added to the accumulated total.
Continue to add measurements by pressing the F3 key as each
measurement is made.
4. To view the accumulated total, press the
The following options are now available:
a. Press
F3
b. Press
F4
c. Press
SEND
NOTE: This Function maintains a running sum of the measurements taken.
Individual measurements in a series cannot be edited or deleted. If an error is
made and an incorrect measurement is taken, the entire summation must be
cleared and repeated. No rounding of inches or millimeters occurs when
configured for feet/inches or meters/millimeters.
Manual Part # 800-1402-002 Rev K, 072418
P
Pr24
ARAMETER
is used to configure this function.
Pr25
key to view any previous accumulator value.
Pr25
is set to 0, and the Readout is in inch mode, (decimal or
is set to 0, and the Readout is in metric mode, (mm or cm),
is set to any non-zero value, and the Readout is in inch
is set to any non-zero value, and the Readout is in metric
key to clear the accumulator.
key. The LCD momentarily displays Add to indicate that
F3
to clear the total and return to the measuring mode.
(DOES NOT clear the total) to return to the measuring mode.
to transmit the accumulated total to the output port.
= 3 to enable this function.
.
key.
F4
key) and the
UNITS
Page 27 of 53

Advertisement

Table of Contents
loading

Table of Contents