Compensation; Temperature Compensation - Accurate Technology ProScale 950 Series Operation

Lcd readouts with firmware version 3.1 and higher
Hide thumbs Also See for ProScale 950 Series:
Table of Contents

Advertisement

Compensation

Temperature and Non-Linear compensation
Functions are ONLY available on General
Purpose (Part # 700-1600-236) and 950 Series
Readouts with firmware ending in 'C".
The firmware version is displayed on power-up, ie P3.000C.

Temperature Compensation

This Function provides automatic compensation of measurement variations
caused by changes in the ambient temperature where the measurement
system is used.
Additionally, coefficients of expansion other than aluminum may be
programmed and the resulting measurement compensated for the different
expansion rates based on a temperature sensor inside the Readout.
Use this feature to maintain the highest measurement accuracy possible when
using the system under wide temperature variations or when mounting the
ProScale aluminum scale extrusion to steel or other surfaces having a different
temperature expansion rate than aluminum.
This function is configured using
To activate Temperature Compensation:
1. Set
Pr41
2. If necessary, enter the expansion coefficient for the material that the
ProScale aluminum Scale is affixed to with
Use care if changing this setting. It will affect system accuracy!
Note: Parameters
with the "Enhanced Accuracy" option.
Manual Part # 800-1402-002 Rev K, 072418
to 1.
&
are preset at the factory for any products ordered
Pr41
44
P
P
ROGRAMMING
ARAMETERS
(Pr41 & Pr44)
.
Pr44
Page 33 of 53