Accurate Technology ProScale 950 Series Quick Start Manual

Flush mount readouts
Hide thumbs Also See for ProScale 950 Series:

Advertisement

Basic Readout, #700-1600-240
General Purpose Enhanced, #700-1600-246
(firmware version ends with "C", even more
features)
Note: This guide applies to ProScale readouts with Firmware Version
4.000 (firmware version is displayed on power-up).
If your readout has a different firmware version, this manual should not
be used. Consult factory for assistance.
QUICK-START GUIDE
ProScale
Flush Mount
Readouts
General Purpose Readout, #700-1600-245
(6 extra keys and more features)
950 Series Readout, #700-1600-M50
(10pin input connector)
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ProScale 950 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Accurate Technology ProScale 950 Series

  • Page 1 ProScale ® Flush Mount Readouts Basic Readout, #700-1600-240 General Purpose Readout, #700-1600-245 (6 extra keys and more features) 950 Series Readout, #700-1600-M50 General Purpose Enhanced, #700-1600-246 (firmware version ends with “C”, even more (10pin input connector) features) Note: This guide applies to ProScale readouts with Firmware Version 4.000 (firmware version is displayed on power-up).
  • Page 2: Date Of Purchase

    Readout serial # ________________ Date of purchase ________________ This Quick Start Guide is intended to help get you started using your new ProScale readout. A more comprehensive manual is available for download from www.proscale.com. Contact factory if additional information is needed. The following programming parameters have been pre-configured at the factory for this readout.
  • Page 3: Installation

    Installation: These Readouts may be mounted several ways: Using Velcro or double-sided tape Use the 3 punch-out holes inside case. Mount readout to machine/panel using #6 or M4 flathead screws. Use any (or all) of the six holes on the back of the readout. Mount using 4-40 or M2 screws.
  • Page 4 Power: These readouts are powered by a single CR123 lithium battery. Unless specially ordered, the readout will deliver to you with the battery installed. New for this version readout: A battery indicator will appear on the left side of the LCD screen. There are 3 tiers of battery shown, which represent the voltage level of the battery.
  • Page 5: Initial Setup

    Initial Setup: Follow these steps to configure your readout for initial use: 1. When the readout is first powered on, it may show a No Enc message. This means there is not an encoder connected to the readout. To clear the message, connect a compatible encoder.
  • Page 6 Primary keys on the readout: All the primary keys on the keypad have multiple functions. What happens on a QUICK PRESS of each key? Action ON/OFF The readout turns on or off. UNITS The units change. Note: Available units can be restricted with custom programming settings.
  • Page 7 Supplemental keys: Some readout models have a supplemental keypad that allows additional features to be used. See below for functions of these keys: Quick press action Press and hold action ABS/INC When in ABS mode, no action. When in ABS mode, toggles readout to INC mode.
  • Page 8 What do all the Symbols mean?: Symbol Meaning The digital readout is operating in Absolute measurement mode. The digital readout is operating in Incremental (temporary) mode. Press and hold ABS/INC key 3 seconds to go back to ABS mode. The readout is in LOCK mode. This prevents loss of calibration if PLUS, MINUS, or DATUM keys are pressed.
  • Page 9 Symbols (continued): When using fractions over 99 inches, one (or both) of these will light to show a value over 100 inches. For example: measurement is 205 5/16. The readout will show 5 5/16 and turn on the +200 indicator. Minus sign.
  • Page 10: Additional Information

    Additional Information: Consult the Complete User Guide at www.proscale.com or contact factory for assistance with any of these more advanced functions: SPC PORT: Position data can be requested by external devices, or sent from readouts equipped with a SEND key. INPUT AND OUTPUT: Input / Output The third terminal on this strip allows for external devices (such as...
  • Page 11: Programming Mode

    Programming Mode: Many features of the readout can be customized, plus additional tools can be configured using the programming menu. Consult the Complete User Guide at www.proscale.com for more information about accessing, changing, and saving customized settings. Before making changes, open the readout case and verify the programming menu is accessible.
  • Page 12 Pr13 Linear multiplier 1.00000 Pr14 Encoder compatibility 1 (Absolute scale) Pr15 LCD contrast adjustment Pr16 Final linear multiplier 1.00000 Pr22 ABS/INC key operation 0 (2 seconds) Pr23 Supplemental keys enabled? 3 (All enabled) Pr24 Monitor/hold, Go/NoGo features 0 (Disabled) Pr25 Go/NoGo values to save 0 (None) Pr26...
  • Page 13: Common Error Messages

    Common Error messages Message What it means no Enc There is not an encoder connected to the readout, or the connected encoder has a fault. no Pos The readout has not been calibrated yet. b fail The battery in the readout needs to be replaced immediately.
  • Page 14 Accessories External Power and I/O plug Part number 200-1016-001. Adds external power and/or input/output capabilities to the readout. Switching power supply Part number 550-2003-001. Provides 15VDC power to the readout. Wireless Data Transmitter Part number 700-1037-001. Transmits measurement values to a remote computer, using Zigbee wireless.
  • Page 15 Popular ProScale Products ProStop is a complete Digital Stop and Fence System for miter and chop saws. It includes an aluminum Fence, a Flip-Stop with fine adjust, double locking mechanism, and Quick-Sets. Many add-on plates available too! ProPanel is a GIANT DIGITAL CALIPER used to make inside, outside, diagonal, hole-edge and hole-hole dimensional measurements.
  • Page 16 Thank you for choosing a ProScale Product, IT WAS PROUDLY MADE IN THE USA Accurate Technology, Inc. 270 Rutledge Rd. Unit E Fletcher, NC 28732 USA 1-828-654-7920 www.proscale.com Operation Manual for ProScale LCD Readouts, version 4 Page 16 of 16...