Go/NoGo

In certain applications, it may be desirable to program upper
and lower measurement tolerances to measure parts. If the
measurement falls within the programmed tolerance, a "Go" condition occurs. If
the measurement is not within the upper or lower tolerance, a "No Go" condition
occurs.
Set Programming Parameter
Programming Parameter
F3 & F4 are used to edit the function parameters.
Programming the Go No/Go Function
The Readout can store up to 16 measurement points (set by
own upper and lower tolerance. Each measurement index is identified with a
number from 1 to 16. The Go/NoGo Editor is used to enter individual upper
and lower tolerances for each measurement point as follows:
1. Press F3 to enter the Editor. The LCD will display Go X where x is a
number from 1 to 16 representing the measurement point to be edited.
(Pressing F3 will increment through the list of points (Pr25), while pressing
F4 will decrement through the list). When the point to be programmed is
reached go to Step 2.
2.
Press and Hold
will display GoX
U indicates the upper tolerance is to be programmed. Use the + and – keys
to set an upper limit, go to Step 3
3. Momentarily press
where X is the measurement index and L indicates the lower tolerance is to
be programmed. Use the
4. After the last point is reached, (determined by Pr25), pressing F3 again will
display Go oFF indicating that the Editor is off.
Operation of Go No/Go Function
To increment through the list of measurement points press
To decrement through the list of measurement points press
To display which measurement index is currently active, press and hold
for 3 seconds. The LCD will display Go X where X is the measurement
F4
index currently active. Once a measurement point is selected, the LCD will
alternate between the current position and Go or no Go depending on the
current position and programmed tolerances for that measurement point.
Operation Manual for LCD Digital Readouts
Pr24
is used to configure this function.
Pr25
the
key and Momentarily press the
UNITS
U for 1 second where X is the measurement point and
. The LCD will now display GoX
F3
and
+
= 2 to enable this function.
keys to set a lower limit, go to Step 4.
, each with its
Pr25)
key. The LCD
F4
L for 1 second
F3.
F4.
F3
Page 26 of 53
or

Advertisement

Table of Contents
loading

Table of Contents