Oil Refilling - probst SH-3500-B Operating Instructions Manual

Vacuum-lifting-device
Table of Contents

Advertisement

Available languages

Available languages

CAUTION
23
22

Oil refilling

Ensure that the oil level gauge (22) is filled at least halfway with oil.
1.
Before refilling, stop the motor (see chapter 6.8).
2.
Vent the vacuum system to ambient pressure.
3.
Open sealing screw (23).
4. Fill with suitable oil until the oil level indicator (22) is more than half-full (see oil type table in the operating and
maintenance instructions of the vacuum pump in the appendix).
5.
Close sealing screw (23).
49
Insufficient maintenance of the vacuum pump
Falling load due to vacuum failure
Check level and color of the oil daily by means of the oil level indicator (22).
Monitor the filter resistance gauge (28), replace oil trap as necessary.
MAINTENANCE
28

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SH-3500-B and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Sh-3500-b-ffs

Table of Contents