CAUTION
23
22
Oil refilling
Ensure that the oil level gauge (22) is filled at least halfway with oil.
1.
Before refilling, stop the motor (see chapter 6.8).
2.
Vent the vacuum system to ambient pressure.
3.
Open sealing screw (23).
4. Fill with suitable oil until the oil level indicator (22) is more than half-full (see oil type table in the operating and
maintenance instructions of the vacuum pump in the appendix).
5.
Close sealing screw (23).
49
Insufficient maintenance of the vacuum pump
Falling load due to vacuum failure
►
Check level and color of the oil daily by means of the oil level indicator (22).
►
Monitor the filter resistance gauge (28), replace oil trap as necessary.