Accessories - WEG CFW-11 Series User Manual

Hide thumbs Also See for CFW-11 Series:
Table of Contents

Advertisement

Observe that the inverters with the external 24 Vdc power supply option use terminals XC1:11 and 13 as the
input for the external power supply and no longer as the output like in the standard inverter (figure 7.2).
In case of interruption of the external 24 Vdc power supply, the digital inputs/outputs and analog outputs will
no longer be fed, even if the mains power is on. Therefore, it is recommended to keep the 24 Vdc power supply
always connected to the terminals XC1:11 and 13.
The keypad displays warnings indicating the inverter status: whether the 24 Vdc power source is connected,
whether the mains power source is connected, etc.
Figure 7.2 - External 24 Vdc power supply capacity and connection terminals
NOTE!
A class 2 power supply must be used in order to comply with the UL508C standard.

7.2 ACCESSORIES

The accessories are installed in the inverter easily and quickly using the "Plug and Play" concept. Once the
accessory is inserted into the slot, the control circuitry identifies its model and displays the installed accessory
code in P0027 or P0028. The accessory must be installed with the inverter power supply off.
24 Vdc
±10 %
@1.5 A
Option Kits and Accessories
XC1 terminal strip
1
+ REF
2
AI1+
3
AI1-
4
- REF
5
AI2+
6
AI2-
7
AO1
8
AGND (24 V)
9
AO2
10
AGND (24 V)
11
DGND *
12
COM
13
24 Vdc
14
COM
15
DI1
16
DI2
17
DI3
18
DI4
19
DI5
20
DI6
21
NC1
DO1
22
C1
(RL1)
23
NO1
24
NC2
DO2
25
C2
(RL2)
26
NO2
27
NC3
DO3
28
C3
(RL3)
29
NO3
7
7-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents