WEG CFW-11 Series User Manual page 41

Hide thumbs Also See for CFW-11 Series:
Table of Contents

Advertisement

Installation and Connection
Terminal Strip
CW
≥5 kΩ
CCW
rpm
3
amp
3-20
XC1
Factory Setting Function
Positive reference for
1
REF+
potentiometer.
2
AI1+
Analog input # 1:
Speed reference (remote).
3
AI1-
Negative reference for
4
REF-
potentiometer.
5
AI2+
Analog input # 2:
No function.
6
AI2-
Analog output # 1:
Speed.
7
AO1
Reference (0 V) for the
AGND
8
analog outputs.
(24 V)
Analog output # 2:
Motor current.
9
AO2
AGND
Reference (0 V) for the
10
analog outputs.
(24 V)
Reference (0 V) for the 24
11
DGND*
Vdc power supply.
Common point of the digital
12
COM
inputs.
24 Vdc power supply.
13
24 Vdc
Common point of the digital
14
COM
inputs.
Digital input # 1:
15
DI1
Start / Stop.
Digital input # 2:
16
DI2
Direction of rotation (remote).
Digital input # 3:
17
DI3
No function.
Digital input # 4:
18
DI4
No function.
Digital input # 5:
19
DI5
Jog (remote).
Digital input # 6:
20
DI6
2nd ramp.
21
NC1
Digital output #1 DO1
(RL1): No fault.
22
C1
23
NO1
24
NC2
Digital output #2 DO2 (RL2):
N > N
- Speed > P0288.
25
C2
X
26
NO2
27
NC3
Digital output #3 DO3 (RL3):
N* > N
- Speed reference
28
C3
X
> P0288.
29
NO3
Figure 3.13 (a) - Signals at connector XC1 - Digital inputs working as "Active High"
Specifications
Output voltage: +5.4 V, ±5 %.
Maximum output current: 2 mA.
Differential
Resolution: 12 bits.
Signal: 0 to 10 V (R
= 400 kΩ) / 0 to 20 mA / 4 to 20 mA (R
IN
Maximum voltage: ±30 V.
Output voltage: -4.7 V, ±5 %.
Maximum output current: 2 mA.
Differential
Resolution: 11 bits + signal.
Signal: 0 to ±10 V (R
= 400 kΩ) / 0 to 20 mA / 4 to 20 mA (R
IN
Maximum voltage: ±30 V.
Galvanic Isolation
Resolution: 11 bits.
Signal: 0 to 10 V (R
≥ 10 kΩ) / 0 to 20 mA / 4 to 20 mA (R
L
Protected against short-circuit.
Connected to the ground (frame) through an impedance: 940 Ω resistor
in parallel with a 22 nF capacitor.
Galvanic Isolation
Resolution: 11 bits.
Signal: 0 to 10 V (R
≥ 10 kΩ) / 0 to 20 mA / 4 to 20 mA (R
L
Protected against short-circuit.
Connected to the ground (frame) through an impedance: 940 Ω resistor
in parallel with a 22 nF capacitor.
Connected to the ground (frame) through an impedance: 940 Ω resistor
in parallel with a 22 nF capacitor.
24 Vdc power supply, ±8 %.
Capacity: 500 mA.
Note: In the models with the 24 Vdc external control power supply
(CFW11XXXXXXOW) the terminal 13 of XC1 becomes an input, i.e., the
user must connect a 24 V power supply for the inverter (refer to the section
7.1.2 for more details). In all the other models this terminal is an output,
i.e., the user has a 24 Vdc power supply available there.
6 isolated digital inputs
High level ≥ 18 V.
Low level ≤ 3 V.
Maximum input voltage = 30 V.
Input current: 11 mA @ 24 Vdc.
Contact rating:
Maximum voltage: 240 Vac.
Maximum current: 1 A.
NC - Normally closed contact;
C - Common;
NO - Normally open contact.
= 500 Ω).
IN
= 500 Ω).
IN
≤ 500 Ω).
L
≤ 500 Ω).
L