RS-232 Configuration and Telnet Commands
COMMAND
ACTION
EDID xx CP yy
Set Input xx EDID Copy From Output yy
Save EDID File From PC Into User Slot zz
EDID SAVE zz
zz=22: User EDID 1
zz=23: User EDID 2
Set Relay xx to Mode yy
xx = 00 : All Relays
xx = 01 : Relay 1
RELAY xx MODE yy
xx = 02 : Relay 2
yy = 01 : Disable NO And Enable NC
yy = 02 : Enable NO And Disable NC
Set The Relay Delay 1 Time To xxx.(Default 10s,
Range From 3s To 180s) Triggered When System On.
RELAY1 xxx
If xxx = 000 Relay 1 Will Remain Active Until System
Off(For Fixed 5V/12V Signal Sensing).
Set The Relay Delay 2 Time To xxx.(Default 10s,
RELAY2 xxx
Range From 3s To 180s) Triggered When System Off.
OUT xx PON
Send Output xx CEC And RS232 Power On Command
OUT xx POFF
Send Output xx CEC And RS232 Power Off Command
OUT xx VOLUP
Send Output xx CEC And RS232 Vol Up Command
OUT xx VOLDOWN
Send Output xx CEC And RS232 Vol Down Command
OUT xx MUTE
Send Output xx CEC And RS232 Mute Toggle
Send Output xx CEC Input Channel yy
xx = 01 : RX HDMI Output
OUT xx INPUT yy
yy = 00 : Next HDMI Channel
yy = [01...15] : HDMI Channel 01 To HDMI Channel 15
Send Input xx CEC Power Toggle Command
IN xx CEC POWER
xx = 01 : TX HDMI Input
xx = 02 : RX HDMI Input
Set RS232 Baud Rate To z
RS232BAUD z
z = 1 2400, 2 4800, 3 9600, 4 19200, 5 38400, 6 57600
(default), 7 115200"
18
COMMAND
RS232ON x:y:z:a
RS232OFF y:z:a
RS232ON DISABLE
RS232OFF DISABLE
RS232RPT x
RS232RPTDLY xx
RS232INPUTDLY xx
NET IP
xxx.xxx.xxx.xxx
NET GW
xxx.xxx.xxx.xxx
NET SM
xxx.xxx.xxx.xxx
NET RB
NET TN xxxx
NET DHCP ON/OFF
www.blustream.com.au | www.blustream-us.com | www.blustream.co.uk
HEX70HDU-KIT
USER MANUAL
ACTION
Send y Type Of Command a Stored In Slot x Whose
Baud Rate Is z
x = 1 Send RS232 Display On
x = 2 Send RS232 Display Input Select
x = 3 Send RS232 User Command 1
x = 4 Send RS232 User Command 2
x = 5 Send RS232 Volume Up
x = 6 Send RS232 Volume Down
x = 7 Send RS232 Volume Mute
y = a ASCII, h HEX
z = 1 2400, 2 4800, 3 9600, 4 19200, 5 38400, 6 57600
(Default), 7 115200
a = RS232 Command
Set RS232 Off Command a Of y Type Whose Baud
Rate Is z
y = a ASCII, h HEX
z = 1 2400, 2 4800, 3 9600, 4 19200, 5 38400, 6 57600
(Default), 7 115200
a = RS232 command
Disable Auto RS232 Commands When Detecting A
Signal
Disable Auto RS232 Commands When Not Detecting
A Signal
Set x Number Of Times RS232 OFF Command Is
Repeated (Default 1 Time, Range From 1 Time To 2
Times)
Set The Sending Interval Time In xx Second(s)
Between RS232 OFFs (Default 2s, Range From 1s To
10s)
Set The Sending Interval Time In xx Second(s)
Between RS232 ONs (Default 10s, Range From 1s To
30s)
Set IP Address
Set Gateway Address
Set Subnet Mask Address
Set Network Reboot and Apply New Config
Set Telnet Port
Set Auto IP(DHCP) ON Or OFF
Need help?
Do you have a question about the HEX70HDU-KIT and is the answer not in the manual?
Questions and answers