Securing the chassis in a flush-mount configuration

Mount the Virtual Services Platform 9010 in a standard two-post or four-post equipment rack. This
procedure aligns the chassis front with the rack.
Procedure
1. Hold the chassis in position and align the flanged end of the chassis mounting bracket with
the holes on either side of the vertical rack support.
2. Ensure that the hole pairs on either side of the rack vertical supports match horizontally.
3. Insert a Phillips screw through each hole on the mounting bracket in the screw positions in
the flange and rack.
4. Tighten each screw with a Phillips screwdriver.
October 2015
Virtual Services Platform 9010 chassis installation