Product provided by Avaya including the selection, arrangement and time and has no control over the availability of the linked pages. design of the content is owned either by Avaya or its licensors and is protected by copyright and other intellectual property laws including the Warranty sui generis rights relating to the protection of databases.
Page 3
Marks of Avaya, its affiliates, or other third parties. Users are not permitted to use such Marks without prior written consent from Avaya or such third party which may own the Mark. Nothing contained in this site, the Documentation and Product(s)
Page 4
Installation — Cooling Modules June 2013 Comments? infodev@avaya.com...
Cooling module fan safety warning statement..................45 Chapter 7: Customer service..................... Getting technical documentation....................... 49 Getting product training..........................49 Getting help from a distributor or reseller....................49 Getting technical support from the Avaya Web site.................. 49 Installation — Cooling Modules June 2013...
Page 6
Installation — Cooling Modules June 2013...
Avaya is not responsible for any modifications to the product made on or for use on the territory of Russia, Belarus and Kazakhstan other than modifications executed and certified by Avaya itself.
EN 55024 Statement This is to certify that the Virtual Services Platform 9000 chassis is shielded against the susceptibility to radio interference in accordance with the application of Council Directive 2004/108/EC.
BSMI statement (Taiwan only) EN 300386 Statement The Virtual Services Platform 9000 chassis complies with the requirements of EN 300386 V1.3.3 for emissions and for immunity for a Class A device intended for use in either Telecommunications centre or locations other than telecommunications centres given the performance criteria as specified by the manufacturer.
Electrostatic alert: Risk of equipment damage To prevent damage from electrostatic discharge, always wear an antistatic wrist strap connected to an ESD jack when connecting cables or performing maintenance on this device. Installation — Cooling Modules June 2013 Comments? infodev@avaya.com...
CE Marking Statement (Europe only) EN 60 950 Statement This is to certify that the Virtual Services Platform 9000 chassis and components installed within the chassis are in compliance with the requirements of EN 60 950 in accordance with the Low Voltage Directive. Additional national differences for all European Union countries have been evaluated for compliance.
Norma Oficial Mexicana (NOM): Exportador: Avaya Inc. 4655 Great America Parkway Santa Clara, CA 95054 USA Importador: Avaya Communication de México SA de CV Av. Presidente Masarik 111 Piso 6 Col Chapultepec Morales Deleg. Miguel HIdalgo México D.F. 11570...
RoHS Directive are Lead (including solder used in PCB's), Cadmium, Mercury, Hexavalent Chromium, and Bromine. Avaya declares compliance with the European Union (EU) RoHS Directive (2002/95/EC) in that Lead, which is a restricted hazardous substance, is used only in accordance to the exemption(s) to Articile 4(1), item 7 granted by the European Union (EU) RoHS DIrective (2002/95/EC) in the Annex—”lead in solders for network infrastructure equipment for switching,...
EC). Safety Messages This section describes the different precautionary notices used in this document. This section also contains precautionary notices that you must read for safe operation of the Avaya Virtual Services Platform 9000. Notices Notice paragraphs alert you about issues that require your attention. The following sections describe the types of notices.
Page 15
Electrostatic alert: PRECAUCIÓN ESD (Descarga electrostática) El aviso de ESD brinda información acerca de cómo evitar una descarga de electricidad estática y el daño posterior a los productos Avaya. Electrostatic alert: CUIDADO ESD Os avisos do ESD oferecem informações sobre como evitar descarga de eletricidade estática e os conseqüentes danos aos produtos da Avaya.
Page 16
Schäden an Avaya-Produkten verhindert. Caution: PRECAUCIÓN Los avisos de Precaución brindan información acerca de cómo evitar posibles interrupciones del servicio o el daño a los productos Avaya. Caution: CUIDADO Os avisos de cuidado oferecem informações sobre como evitar possíveis interrupções do serviço ou danos aos produtos da Avaya.
Page 17
Avaya. Warning: AVVISO Le indicazioni di avviso forniscono informazioni per evitare danni alle persone durante l'utilizzo dei prodotti Avaya. Danger High Voltage Notice Voltage: Danger—High Voltage notices provide information about how to avoid a situation or condition that can cause serious personal injury or death from high voltage or electric shock.
Page 18
Avisos de perigo oferecem informações sobre como evitar uma situação ou condição que possa causar graves ferimentos ou morte. Danger: PERICOLO Le indicazioni di pericolo forniscono informazioni per evitare situazioni o condizioni che potrebbero causare gravi danni alle persone o il decesso. Installation — Cooling Modules June 2013 Comments? infodev@avaya.com...
Chapter 2: Purpose of this document The Avaya Virtual Services Platform 9000 chassis includes IO and SF cooling modules to ensure proper cooling of installed interface, Central Processor (CP), and Switch Fabric (SF) modules. Avaya Virtual Services Platform 9000 Installation — Chassis, NN46250-304 provides information about environmental specifications for the chassis.
Page 20
Purpose of this document Installation — Cooling Modules June 2013 Comments? infodev@avaya.com...
Chapter 3: New in this release The following sections describe the changes in Avaya Virtual Services Platform 9000 Installation — Cooling Modules, NN46250–302, for Release 3.3. Features There are no feature-related changes. Other changes See the following sections for changes that are not feature-related.
Page 22
The model names for cooling modules are updated in software and documentation. For more information, see • 9012FC IO cooling module on page 23 • 9012RC SF cooling module on page 25 • Airflow in the 9012 chassis on page 27 Installation — Cooling Modules June 2013 Comments? infodev@avaya.com...
Chapter 4: Cooling module fundamentals This section illustrates the Avaya Virtual Services Platform 9000 cooling modules: Input Output (IO) cooling module and Switch Fabric (SF) cooling module. 9012FC IO cooling module You must install two IO cooling modules in the front of the chassis. The IO cooling modules provide cooling for the interface modules and the Central Processor (CP) modules.
Page 24
Either it is spinning below the FAULT threshold turned on) setting or does not spin at all. The fan tray can still provide enough cooling by increasing the fan speed of the remaining fans. Installation — Cooling Modules June 2013 Comments? infodev@avaya.com...
The SF cooling modules are hot swappable. You can replace them, one at a time, without turning off the Virtual Services Platform 9000. The following figure shows the SF cooling module for the chassis. Figure 2: SF cooling module The 9012RC SF cooling module measures 4.625 inches (in.) x 8.75 in.
Virtual Services Platform 9000 modules are larger and heavier than Ethernet Routing Switch 8000 series modules. Handle the modules used in Virtual Services Platform 9000 with care. Take the following items into consideration when you handle modules: • To prevent damage from electrostatic discharge, always wear an antistatic wrist strap connected to an ESD jack when connecting cables or performing maintenance on this device.
Airflow in the 9012 chassis Airflow in the 9012 chassis Airflow in the Virtual Services Platform 9000 9012 chassis is from left-to-right (as viewed from the front) for I/O modules and front-to-back for switch fabric cards and power supplies. Figure 3: Front of the 9012 chassis...
Page 28
Figure 4: 9012FC cooling module Each 9012FC cooling module has eight fans. The platform polls all line card and CP card sensors and adjusts the 9012FC fan speed accordingly. Installation — Cooling Modules June 2013 Comments? infodev@avaya.com...
Page 29
Note: Do not place the 9012 chassis directly against a wall, equipment, or other obstruction. Avaya recommends 36 inches (91 centimeters) of free space in both the front and back of the machine and also 6 inches (15.2 centimeters) on each side extra). Depending on the circumstances, increase the free space at the side to allow for more airflow or cool airflow into the 9012 chassis.
Figure 6: Data center floor plan of hot and cold aisles Diagram Description Chassis racks Cold aisle floor tiles in a raised floor Back of chassis Front of chassis Installation — Cooling Modules June 2013 Comments? infodev@avaya.com...
Optimizing cooling in a data center In a data center configuration, the front of equipment faces the cold aisle, while the rear of the equipment faces the hot aisle. The chassis take in cold air from the cold aisle and discharge hot air into the hot aisle.
Page 32
Table 4: Data center with optimized cooling Diagram Description Cooling tiles Back of 9012 chassis Front of 9012 chassis Baffle 5, 7 Hot aisles Cold aisle 8 to 13 Other equipment, front to back cooling Installation — Cooling Modules June 2013 Comments? infodev@avaya.com...
9012 chassis placement 9012 chassis placement If you place each 9012 chassis in a row from left to right, then the chassis to the left discharges hot air into the cool intake of the chassis to the right. To optimize airflow, stagger each chassis in racks and add a baffle that redirects hot air discharged by a chassis from the side to the hot aisle at the back.
As a result, the cooling module can only offer 50 per cent of the cooling airflow. Figure 9: Cooling module cable management Diagram Description Cable management blocking fan Fans Installation — Cooling Modules June 2013 Comments? infodev@avaya.com...
Clearance Do not place the 9012 chassis directly against a wall, equipment, or other obstruction. Avaya recommends 36 inches (91 centimeters) of free space in both the front and back of the machine and also 6 inches (15.2 centimeters) on each side). However, dependent on circumstances, increase the space at the side of the 9012 chassis to improve airflow.
Page 36
(above and below) the threshold temperature. The zone alarm clears after the temperature falls below 50 °C. Installation — Cooling Modules June 2013 Comments? infodev@avaya.com...
Chapter 5: Cooling module installation and removal This section describes how to install the cooling modules in the Avaya Virtual Services Platform 9000. Install a cooling module to provide cooling to the interface, Switch Fabric (SF), and Central Processor (CP) modules. Installation takes 2 to 5 minutes.
Removing the I/O cooling module Remove the I/O cooling module from the slot at the front of the chassis to replace it. You can hot swap the cooling modules. Warning: Risk of personal injury Installation — Cooling Modules June 2013 Comments? infodev@avaya.com...
Installing the SF cooling module Remove the cooling modules using the provided handles. Be careful to keep your fingers out of the fan blades. When you remove a cooling module, allow time for the fans to spin down before you fully withdraw the cooling module. Procedure 1.
4. Verify that the cooling module LED light is green. Removing the SF cooling module Remove the SF cooling module from the slot to remove it. You can hot swap the cooling modules. Installation — Cooling Modules June 2013 Comments? infodev@avaya.com...
Page 41
Removing the SF cooling module Warning: Risk of personal injury Remove the cooling modules using the provided handles. Be careful to keep your fingers out of the fan blades. When you remove a cooling module, allow time for the fans to spin down before you fully withdraw the cooling module.
Page 42
Cooling module installation and removal Installation — Cooling Modules June 2013 Comments? infodev@avaya.com...
Chapter 6: Translations of safety messages This chapter describes the translations of safety messages which you need to be aware of while executing the installation of AC power supply. Class A electromagnetic interference caution statement Caution: Risk of electromagnetic interference This device is a Class A product.
à une prise pour décharge électrostatique (ESD) lors de l’exécution d’opérations de maintenance sur ce produit. Assurez-vous que le bracelet antistatique est en contact avec votre peau. Electrostatic alert: ACHTUNG Installation — Cooling Modules June 2013 Comments? infodev@avaya.com...
Cooling module fan safety warning statement Um Schäden durch elektrostatische Entladung zu verhindern, tragen Sie bei der Instandhaltung dieses Produkts immer ein antistatisches Band am Handgelenk, das mit einer ESD-Buchse verbunden ist. Stellen Sie Electrostatic alert: PRECAUCIÓN ESD (Descarga electrostática) Para prevenir el daño producido por una descarga electrostática, use siempre una pulsera antiestática conectada a un enchufe de descarga electrostática (ESD) al realizar el mantenimiento de este producto.
Page 46
Quando remover um módulo de refrigeração, espere um pouco para que as pás parem de girar antes de retirar totalmente o módulo de refrigeração. Warning: Avvertenza Rischio di lesion personali Installation — Cooling Modules June 2013 Comments? infodev@avaya.com...
Page 47
Cooling module fan safety warning statement Rimuovere I moduli di raffreddamento utilizzando i supporti in dotazione. Fare attenzione a non avvicinare le dita alle lame della ventola. In fase di rimozione del modulo di raffreddamento, prima di estrarlo completamente, attendere che le ventole rallentino. Installation —...
Page 48
Translations of safety messages Installation — Cooling Modules June 2013 Comments? infodev@avaya.com...
Chapter 7: Customer service Visit the Avaya Web site to access the complete range of services and support that Avaya provides. Go www.avaya.com or go to one of the pages listed in the following sections. Getting technical documentation To download and print selected technical publications and release notes directly from the Internet, go to www.avaya.com/support.
Page 50
Customer service Installation — Cooling Modules June 2013 Comments? infodev@avaya.com...