Configure The Océ Tds7X0 System For Use With Océ Power Logic Remote - Canon Oce TDS Series Administration Manual

Table of Contents

Advertisement

Configure the Océ TDS7x0 system for use with Océ Power Logic Remote
Configure the Océ TDS7x0 system for use with Océ Power Logic
Remote
Illustration
[2] Océ TDS7x0 system configuration for use with Océ Power Logic Remote
NOTE
The procedure for the Océ TDS7x0 system also applies to the Océ TC4 system.
Procedure
1. From the Océ TDS7x0 Power Logic Controller application on the printer controller, click 'Edit' and
'Options'.
The 'Options' window opens.
2. Check the 'Host name' field:
If the 'Host name' field
is empty or 'Auto detected'
is not empty or 'Auto de-
tected'
Result
If the empty 'Host name' field causes Océ Remote Logic or Océ Power Logic Remote connectivity
problems:
• Select the Océ TDS/TCS system hostname or IP address from the drop down list.
• Click 'OK' and restart the Océ TDS/TCS system controller.
44
Chapter 2 - Configure the print system controller
Then
the configuration of the Océ TDS7x0 system is correct for use with
Océ Power Logic Remote.
1. Open the drop down list.
2. Select the empty line or 'Auto detected'.
3. Click 'OK'.
4. Restart the Océ TDS7x0 printer controller.
Océ TDS/TCS/TC Connectivity information for Windows environments

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents