Pulsr A Vol Code; Pulsr B Vol Code; Pulsr C Vol Code; Cor Vol Disp Res - Honeywell Mini-AT User Manual

High performance, ptz electronic volume corrector
Table of Contents

Advertisement

Item
No.
Item Name
————————————————————————————————————————
093

PULSR A VOL CODE

094

PULSR B VOL CODE

095

PULSR C VOL CODE

096

COR VOL DISP RES

097
UNC VOL DISP RES
098
METER INDEX CODE
www.honeywell.com
100
Mini-AT User Guide
Description
Code (0-4) that selects the type of pulse information to be
transmitted out Pulser Channel A.
Code (0-4) that selects the type of pulse information to be
transmitted out Pulser Channel B.
Code (0-4) that selects the type of pulse information to be
transmitted out Pulser Channel C.
Possible selections for items 093, 094 and 095:
Select: 0 - COR VOL
1 - PCor VOL
2 - UNC VOL
Code (0-4) that selects the number of digits (out of eight) to be
blanked on the left-side of the corrected volume display (item
000).
Select: 0 - NO BLANKS--Default
1 - 1 BLANK
2 - 2 BLANK
3 - 3 BLANK
4 - 4 BLANK
Code (0-4) that selects the number of digits (out of eight) to be
blanked on the left-side of the uncorrected volume display
(item 002).
Select: 0 - NO BLANKS--Default
1 - 1 BLANK
2 - 2 BLANK
3 - 3 BLANK
4 - 4 BLANK
Code (0-8) that selects the value of each uncorrected input pulse.
The selection should agree with the gas meter drive rate, i.e. the
amount of uncorrected volume per output shaft rotation (or meter
pulse).
Select: 0 - 1 CF
1 - 5 CF
2 - 10 CF------Default
3 - 100 CF
4 - 1000 CF
3 - NO OUTPUT
Default
4 - TIME
Example:
12345678
2345678
345678
45678
5678
Example:
12345678
2345678
345678
45678
5678
5 - .1m3
6 - 1 m3
7 - 10 m3
8 - 100 m3