Audit Trail; Number Of Days Available For Audit Trail - Honeywell Mini-AT User Manual

High performance, ptz electronic volume corrector
Table of Contents

Advertisement

Audit Trail

The Mini-AT records operational information on a user-selectable interval. At the beginning of each INTER-
VAL (item 202), the instrument records either four or ten items into memory. The default settings are:
Selectable Report Items
1. Item Code 258:
2. Item Code 259:
3. Item Code 260:
4. Item Code 261:
Optional Report Items
1. Item Code 229:
2. Item Code 230:
3. Item Code 231:
4. Item Code 232:
5. Item Code 233:
6. Item Code 234:
The Mini-AT will store 140 days of hourly information for these ten items. After 140 days, the earliest
information will begin to be overwritten by new information. The Audit Trail can be downloaded using the
Mini-AT Link software (or MasterLink32).
The Audit trail items can be changed using Mini-AT Link software and changing Item Codes 258-261 and
229-234. Any Mini-AT item can be selected for the Audit Trail. Assigning"255" to items 229-234 will
configure the instrument RAM memory to the four item configuration.
Selected
(Item 202)
15 Minutes
30 Minutes
60 Minutes
24 Hours
Mini-AT User Guide
225
Incremental Corrected Volume
226
Incremental Uncorrected Volume
206
Average Pressure
207
Average Temperature
048
Battery Voltage
000
Corrected Volume
002
Uncorrected Volume
008
PCor Gas Pressure
026
Gas Temperature
059
Battery Wake Cycles
Number of Days Available
per download type
Interval
4 Item
65 Days
130 Days
260 Days
6240 Days
Table 8

Number of Days Available for Audit Trail

10 Item
35 Days
70 Days
140 Days
3360 Days