Item
No.
Item Name
————————————————————————————————————————
222
DAILY CORVOL ALM
223
DAILY CORVOL
224
DAILY UNCVOL
225
INCREMNTL CORVOL
226
INCREMNTL UNCVOL
www.honeywell.com
122
Mini-AT User Guide
Description
During a wake cycle, if the computed value for item 223 (DAILY
CORVOL) is greater than the value at item 221 (DAILY
CORVOL LIMIT), an alarm is initiated and is indicated by
placing dots on the LCD and "11111111" at item 222.
"00000000" at item 222 indicates there is no Daily CorVol
Alarm. The alarm and alarm indicators are automatically
cleared at the beginning of each Gas Day, regardless if RBX
(item 165) is enabled or not.
Default = 00000000
Same as CORVOL (item 000) but is initialized (re-zeroed) at the
START TIME (item 205) of each Gas Day. If the instrument is
accessed, this item will display the current value for that point in
time.
Default = 00000000
Same as UNCVOL (item 002) but is initialized (re-zeroed) at the
START TIME (item 205) of each Gas Day. If the instrument is
accessed, this item will display the current value for that point in
time.
Default = 00000000
Same as CORVOL (item 000) but is initialized (re-zeroed) at the
beginning of every TIME-triggered wake-up (item 202). If the
instrument is accessed, this item will display the current value for
that point in time.
Default = 00000000
Same as UNCVOL (item 002) but is initialized (re-zeroed) at the
beginning of every TIME-triggered wake-up (item 202). If the
instrument is accessed, this item will display the current value for
that point in time.
Default = 00000000