Wiring Connections For Rsi Board - Honeywell Mini-AT User Manual

High performance, ptz electronic volume corrector
Table of Contents

Advertisement

www.honeywell.com
24
Mini-AT User Guide
Terminal Single Switch Dual Switch
TB1-1
TB1-2
TB1-3
TB1-4
TB1-5
TB1-6
TB1-7
Terminal Single Switch Dual Switch
TB1-1
TB1-2
TB1-3
TB1-4
TB1-5
TB1-6
TB1-7

Wiring Connections for RSI Board

Note: NO = Normally Open
NC = Normally Closed
N/C = No Connection
COM = Commmon
Form A
SW1-NO
SW1-NO
N/C
N/C
SW1-COM
SW1-COM
TB1-1
SW2-NO
N/C
N/C
N/C
SW2-COM
Cable Shield Cable Shield
Form C
SW1-NO
SW1-NO
SW1-NC
SW1-NC
SW1-COM
SW1-COM
TB1-1
SW2-NO
TB1-2
SW2-NC
TB1-3
SW2-COM
Cable Shield Cable Shield
Table 1
SW1 = Switch # 1
SW2 = Switch # 2
TB1 = Terminal Block #1 on RSI Board

Hide quick links: