Plog Avg Press; Intvl Plog P High; Intvl Plog P Low; Plog Max Press - Honeywell Mini-AT User Manual

High performance, ptz electronic volume corrector
Table of Contents

Advertisement

Item
No.
Item Name
————————————————————————————————————————
421

PLOG AVG PRESS

422

INTVL PLOG P HIGH

423

INTVL PLOG P LOW

426

PLOG MAX PRESS

427
PLOG MAX PRESS TIME
428
PLOG MAX PRESS DATE
429
PLOG MIN PRESS
430
PLOG MIN PRESS TIME
431
PLOG MIN PRESS DATE
Mini-AT User Guide
Description
Calculated PLog average pressure for the time interval
selected at item 202. The average value is time weighted over
the PLog SAMPLE INTERVAL selected at item 401.
Default = 0.00
Highest PLog Gas Pressure (item 420) measured during the
Time Interval selected at item 202. The value at item 422 is
initialized (re-zeroed) at the beginning of each new log
interval.
Default = 0.00
Lowest PLog Gas Pressure (item 420) measured during the
Time Interval selected at item 202. The value at item 422 is
initialized (re-zeroed) at the beginning of each new log
interval.
Default = 099999.99
The highest value of PLog Gas Pressure since the last manual
reset.
Default = 0.00
The time when PLog MAX PRESS (item 426) occurred.
Default = 00 00 00 (Format: HH:MM:SS)
The date when PLog MAX PRESS (item 426) occurred.
Default = 01-01-98
The lowest value of PLog Gas Pressure since the last manual
reset.
Default = 99999.99
The time when PLog MIN PRESS (item 429) occurred.
Default = 00 00 00 (Format: HH:MM:SS)
The date when PLog MIN PRESS (item 429) occurred.
Default = 01-01-98