Honeywell Mini-AT User Manual page 97

High performance, ptz electronic volume corrector
Table of Contents

Advertisement

Item
No.
Item Name
————————————————————————————————————————
071
PULSER C ALARM
072
ALARM 1 ITEM #
073
ALARM 2 ITEM #
074
ALARM 3 ITEM #
075
MAG LIST 2 ITM 1
076
MAG LIST 2 ITM 2
077
MAG LIST 2 ITM 3
Mini-AT User Guide
Description
If the value at item 007 (Pulser C) exceeds the Pulser C Limit (item
071), an alarm is initiated. The LCD will display 'dots' while in
the Corrector Mode, and item 071 will display "11111111" if view
by the Meter Reader Mode or software. "00000000" is displayed
if item 071 has no alarm.
Default = 00000000
Item number for the first of three user-selectable, optional
alarms. Intended choices are:
000 = unassigned
105 = Pressure Out of Range
106 = Temperature Out of Range
Default = 000
Item number for the second of three user-selectable, optional
alarms. Intended choices are:
000 = unassigned
105 = Pressure Out of Range
106 = Temperature Out of Range
Default = 000
Item number for the third of three user-selectable, optional
alarms. Intended choices are:
000 = unassigned
105 = Pressure Out of Range
106 = Temperature Out of Range
Default = 000
Item number of the first item displayed in MAG LIST #2. The
display of this selection follows the display of LIVE Parameters (if
enabled at item 129) or the last MAG LIST 1 ITEM (if enabled,
items 130-135). If neither LIVE Parameters nor MAG LIST 1
items are enabled, the item programmed into item 075 will be the
first Mag Read Item to be displayed in the Meter Reader List. Any
Mini-AT item number may be entered as a Mag Read Item.
Default = 200 (Site ID number)
Item number of the next Mag List #2 item. Any item code may be
selected, or enter the value "255" at this item to indicate the
End-of-List.
Default = 113 (Hi Res CorVol)
Same as Item 76 above.
Default = 013 (Base Pressure)