Integration
Command Value
(hexadecimal)
0x001D
0x001E
0x001F
0x0020
0x0021
0x0022
0xZ00
0xZ01
0xZ02
0xZ03
0xZ04
0xZ05
0xZ06
0xZ07
0xZ08
0xZ09
0xZ0A
0xZ0B
0xZ0C
0xZ0D
86
Therm-O-Flow Warm Melt Heated Advanced Fieldbus Map
Data Exchange
Pump Lifetime Weight Dispensed
System Runway Cycles Per Minute
System Prime Pump Timeout
System External Pump Control
Pump Prime Timeout Remaining
System Heat Rate
AMZ Active Zone #Z Alarms
AMZ Active Zone #Z Deviations
AMZ Active Zone #Z Advisories
Zone #Z Heat State
Zone #Z Actual Temperature
Zone #Z Actual Current Usage
Zone #Z Actual Duty Cycle
Zone #Z Soak Time Remaining
Zone #Z Setpoint Temperature
Zone #Z Setback Temperature
Zone #Z Heat Soak Time
Zone #Z Heat Enabled/ Installed State
Zone #Z Other Tandem Heat Enabled/Installed
State
Zone #Z Type State
Name
Units/Format
xx grams
xxx cpm
xx seconds
Boolean:
TRUE = Enabled
FALSE = Disabled
xx seconds
Boolean:
TRUE = Enabled
FALSE = Disabled
Bitfield
Bitfield
Bitfield
Bit Number:
0: Heat Zone Off
1: Heat Zone On
2: Heat Zone Warming Up
3: Heat Zone At Temperature
4: Heat Zone is Heat Soaking
5: Heat Zone is in Setback
6: Heat Zone has an Error
xx.x deg C
xx.xxx A
xxx%
xx seconds
xx deg C
xx deg C
xx minutes
boolean
boolean
Enum Number:
0: Hose
1: Valve
2: Manifold
3: PGM
4: Flowmeter
5: Press Regulator
6: Other
7: Pump
8: Platen
3A8005A