Graco Therm-O-Flow 200 Instructions - Parts Manual page 57

Warm melt
Hide thumbs Also See for Therm-O-Flow 200:
Table of Contents

Advertisement

Error
Location
Type
CAC_
ADM
Alarm
CBGX
Gateway
Alarm
CBT_
AMZ
Alarm
CBV_
AMZ
Alarm
3A8005A
Error Name
Error Description
Communicatio
Communication lost
n Error U_
between ADM and
Heat Module
Fieldbus
The fieldbus has
Reset
performed a reset
Communicatio
Communication lost
n Error U_D_
between AMZ MZLP4
and ADM
Communicatio
Communication lost
n Error U_D_
between AMZ DB and
ADM
Cause
No 24 VDC
Reconnect or replace
power supply
CAN cable connecting
to ADM
AMZ and ADM. If CAN
connection good, check
24V power supply wiring
in side the heat box.
Make sure AC power to
pump is turned off before
checking power supply.
Yellow LED on AMZ
board should be flashing.
Cross threaded
CAN cables carry 24 V
CAN cable.
DC power and
communication between
modules. A cross
threaded CAN cable
connector may cause
problems with
communication and/or
power to modules.
Carefully check for cross
threaded CAN
connections on the ADM
and AMZ. Yellow LED on
AMZ board should be
flashing.
Changing the
No action necessary
fieldbus setup
properties
No AC power
Verify AMZ MZLP4 is
to the AMZ
turned on by confirming
MZLP4
disconnect switch of the
heat box is in the ON
position.
Faulty AMZ
Replace AMZ MZLP4
MZLP4 control
control board
board
No AC power
Verify AMZ DB is turned
to the AMZ DB
on by confirming
disconnect switch of the
heat box is in the ON
position.
Faulty AMZ DB
Replace AMZ DB control
control board
board
Troubleshooting
Solution
57