Graco Therm-O-Flow 200 Instructions - Parts Manual page 62

Warm melt
Hide thumbs Also See for Therm-O-Flow 200:
Table of Contents

Advertisement

Troubleshooting
Error
Location
Type
T9__
AMZ
Alarm
V2H_
AMZ
Deviation
V4H_
AMZ
Alarm
V6H_
AMZ
Alarm
WMG0
Gateway
Alarm
WNG0
Gateway
Alarm
WSU0
ADM
Alarm
DAP_
Pump
Alarm
62
Error Name
Error Description
Over
The zone over
Temperature
temperature switch
Switch Error
triggered
U_Z_
Low Voltage
The incoming power of
U_D_
the unit is below
minimum acceptable
limit
High Voltage
The incoming power of
U_D_
the unit is above
minimum acceptable
limit
Wiring Error
The wiring of the unit is
U_D_
invalided from what the
AMZ is expecting
Gateway
Gateway error
Error
detected; includes any
Detected
error not covered by a
more specific error
Gateway Map
Missing or invalid
Error
gateway map
USB
USB configuration file
Configuration
not detected
Error
Pump
Pump Runaway
Runaway U_
Detected
Cause
The zone over
Plug back in.
temperature
switch is wires
are unplugged
The zone
Cool pump down.
temperature is
to high
Fault over
Replace over
temperature
temperature switch.
switch
Incoming line
Verify incoming power is
to line voltage
correct gauge for current
has dropped
draw and verify incoming
below 175V
power lines are securely
attached to disconnect.
Incoming line
For 3 phase with neutral
to line voltage
have qualified electrician
has increased
verify neutral wire.
above 265V
Wrong wiring
Verify incoming power is
of the power
wired to the disconnect
source to the
correctly per the manual.
AMZ
---
---
Missing or
Install map in gateway.
invalid gateway
map
USB
Update software to the
congifuration
latest available on
file not loaded
help.graco.com.
or was deleted
Pump is trying
Adjust the drum empty
to feed
level sensor to detect an
material, no
empty state.
material to feed
Ensure the ram director
valve is in the down
position and sufficient air
is forcing the ram down.
Worn or
Inspect pump seals and
damaged
replace if necessary.
pump seals
Solution
3A8005A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Therm-o-flow 20