Troubleshooting
Error
Location
Type
A1__
AMZ
Alarm
A2__
AMZ
Advisory
A3__
AMZ
Alarm
A4__
AMZ
Alarm
A7__
AMZ
Alarm
A8__
AMZ
Alarm
56
Error Name
Error Description
Low Current
Heater current is below
U_Z_
the minimum allowed
value
Low Current
Heater current is below
U_Z_
the minimum allowed
value
High Current
Heater current
U_Z_
exceeds maximum
allowed value
High Current
Heater current
U_Z_
exceeds maximum
allowed value
Unexpected
Heat current has an
Current U_Z_
unexpected current
flow
No Current
Power is not getting to
U_Z_
heating element
Cause
Fault heater
Check heater resistance
element
and resistance to
ground. Replace faulty
heater
Fault heater
Check heater resistance
element
and resistance to
ground. Replace faulty
heater
Heater element
Replace heater element
is defective
Heater element
Check wiring to the
is shorted
heater element to ensure
no bare wires are
touching and that no
wires are shorted to
ground
Heater element
Replace heater element
is defective
Heater element
Check wiring to the
is shorted
heater element to ensure
no bare wires are
touching and that no
wires are shorted to
ground
Unexpected
Fault heater element.
Current flow to
Check heater resistance
the heat
and resistance to
element
ground. Replace heater
element
Faulty AMZ, Replace
AMZ
Power not
Check fuse on the AMZ
getting to
that the error element is
heating
connected to
element
Check that electrical
connector on the heated
hose is plugged into the
AMZ
Check continuity of pins
on electrical connector at
AMZ end of heated
element. See heated
element manual for
impedance
measurements and pin
outs. Replace hose if
readings are to high
Solution