Graco Therm-O-Flow 200 Instructions - Parts Manual page 61

Warm melt
Hide thumbs Also See for Therm-O-Flow 200:
Table of Contents

Advertisement

Error
Location
Type
T3__
AMZ
Advisory
T4__
AMZ
Alarm
T4T_
DB
Alarm
T6__
AMZ
Alarm
T6T_
DB
Alarm
T8__
AMZ
Alarm
3A8005A
Error Name
Error Description
High
The zone temperature
Temperature
has exceeded the
U_Z_
setpoint
High
The zone temperature
Temperature
has exceeded the
U_Z_
setpoint
High
The transformer cord
Temperature
temperature is to high
Transformer
U_
Sensor Error
The zone has no
U_Z_
reading from RTD
Sensor Error
The transformer has
Transformer
no temperature
U_
reading
No
The zone temperature
Temperature
does not changed
Rise U_Z_
Cause
Element
Defective RTD. Replace.
continues to
raise above the
setpoint
RTD not in
See manual to find
correct location
correct location of RTD
on element
on element.
Temperature
Adjust the temp Offset
reading has
Error in the Heat setup
risen too high
screen
Element
Defective RTD. Replace.
continues to
raise above the
setpoint
RTD not in
See manual to find
correct location
correct location of RTD
on element
on element.
Temperature
Adjust the temp Offset
reading has
Error in the Heat setup
risen too high
screen.
Transformer
Cool down transformer.
temperature is
too high
No reading
Check the wired
from the RTD
connections to make
of the heat
sure that RTD is wired
zone
correctly.
Defective RTD. Replace.
No reading
Check the wired
from the RTD
connections to make
of the heat
sure that RTD is wired
zone
correctly.
Defective RTD. Replace.
The zone
Check fuse on the AMZ
temperature
that the error element is
does not
connected to.
changed
Check that electrical
connector on the heated
hose is plugged into the
AMZ.
Defective heater rods in
element. Replace.
Troubleshooting
Solution
61