Graco Therm-O-Flow 200 Instructions - Parts Manual page 84

Warm melt
Hide thumbs Also See for Therm-O-Flow 200:
Table of Contents

Advertisement

Integration
Automation Outputs (signal from PLC to Therm-O-Flow Warm Melt)
Instance ID
33
Data Exchange Command
34
Data Exchanged Command Desired Value
35
Heat On Request
36
Heat Off Request
37
Heat Setback Request
38
Pump Off Request
39
Pump Prime Request
40
Acknowledge/Clear Heat Errors
41
Reserved Bit 1
42
Reserved Bit 2
43
Reserved Bit 3
44
Reserved Bit 4
45
Reserved Bit 5
46
Reserved Bit 6
47
Reserved Bit 7
48
Reserved Bit 8
49
Reserved Bit 9
50
Reserved Bit 10
51
Data Exchange Command
52
Data Exchanged Command Desired Value
Key
System
Active Unit
Inactive Unit
84
Therm-O-Flow Warm Melt Heated Advanced Fieldbus Map
Description
Data Type
Bit
uint16
0-15
uint32
0-31
Boolean
0
Boolean
1
Boolean
2
Boolean
3
Boolean
4
Boolean
5
Boolean
6
Boolean
7
Boolean
0
Boolean
1
Boolean
2
Boolean
3
Boolean
4
Boolean
5
Boolean
6
Boolean
7
uint16
0-15
uint32
0-31
Byte
4-5
6-9
10
11
12-13
14-17
3A8005A