Error
Location
Type
DDP_
Pump
Deviation
L1P_
Pump
Deviation
DEP_
Pump
Alarm
WKP_
Pump
Alarm
3A8005A
Error Name
Error Description
Pump Diving
Pump Diving Detected
U_
Pump Level
Pump Level Sensor
Sensor Error
Error Detected
U_
Pump Reed
Pump Reed Switch
Switch Error
Failure Detected
U_
Fill Solenoid
Fill Solenoid
Disconnection
Disconnected
Error U_
Detected
Cause
Pump is trying
Adjust the drum empty
to feed
level sensor to detect an
material, no
empty state.
material to feed
Ensure the ram director
valve is in the down
position and sufficient air
is forcing the ram down.
Worn or
Inspect pump seals and
damaged
replace if necessary.
pump seals
Machine is
Make sure the empty
detecting an
level sensor is not
empty state,
covered in material.
without a low
Verify the low level
state
sensor is plugged into
correct location. See
manual for connection
spot.
Verify the low level
sensor is close enough
to the metal bar; adjust if
necessary.
Replace sensors.
Reed switch
Check that sensor cable
failed
is plugged into correct
location. See manual for
connection spot.
Check for loose
connection at reed
switch.
Ensure reed switch is
securely attached to the
air motor.
Replace if necessary.
Fill is not
Verify harness is
turning on
plugged into the
when it should
correction location. See
manual for connection
spot.
Verify that the solenoid is
secured correctly.
Replace Solenoid.
Troubleshooting
Solution
63