Users - RACOM RAy3 User Manual

Microwave link
Hide thumbs Also See for RAy3:
Table of Contents

Advertisement

Configuration

5.4.3.3. Users

List and setup of users. Example menu of the cli_super level user.
Fig. 5.12: Menu Link settings / Service access / Users
Within the default Factory Settings one user is defined in the system. This user has username admin
and password admin and is assigned the highest level of permissions cli_super. This user then
assigns other users to the system along with their level of permissions.
Service access has three groups of users with different levels of permissions.
Permissions
Create new user
Change own password
Delete user *
Copy (Mirror) permissions local to peer
Configure and modify link settings
Numbers of users that can be defined in the system:
Group
cli_guest
cli_admin
cli_super *
* The system prevents the user from deleting both cli_super accounts.
The logged-on user is shown in the top right of the screen. There can be different users on either end
of the link.
Important
It is strongly recommended that the default password admin is changed. Similarly, all other
users should change their password. Using the CLI, it is appropriate to supplement the SSH
key.
96
No of users
10
10
2
cli_guest
cli_admin
No
No
Yes
Yes
No
No
No
No
No
Yes
RAy3 Microwave Link – © RACOM s.r.o.
cli_super
Yes
Yes
Yes
Yes
Yes

Advertisement