Radio Loopback - RACOM RAy3 User Manual

Microwave link
Hide thumbs Also See for RAy3:
Table of Contents

Advertisement

Configuration
• Enable
Opening analyzer functions.
• Start
Interrupts communication on the link and starts scanning frequencies in the band.
• Spectrum measure time
Selection of measurement length in range:
• Mute peer TX
The deactivation of Peer station transmission during measurement.
single sweep ... up to 15 min
Note
Single sweep takes about 2 seconds for the whole band scan in 17 or 24 GHz (only 200-250
MHz wide). For licensed bands it takes adequately longer - according the width of RX and TX
parts of the band.
The link is automatically re-established after it is finished.
Warning
Running spectrum measurement causes interruption of user data flow between stations!
Interruption of the scan before selected measure time can be achieved anytime by visiting any of the
Link menu settings and select Refresh. This restores the configuration connection (message Peer:
n/a).

5.6.2.4. Radio loopback

Fig. 5.47: Menu Tools / Live Data / Radio loopback
Radio loopback measurement serves as a check of quality of the antenna connection to the microwave
unit and the quality of the antenna itself. Only available for the 17 GHz and 24 GHz units. The unit
measures the strength of the signal received from its own transmitter. The lower the signal level received,
the better the antenna quality. The user data transmission is interrupted during the measurement. The
remote transmitter (Peer unit) is temporarily muted not to interfere with the measurement.
156
RAy3 Microwave Link – © RACOM s.r.o.