Configuration

5.5. Switch settings

Ethernet switch is a key part of the RAy3 unit. It is responsible for data transfer inside the unit - see
Appendix B, Unit block diagrams.

5.5.1. Status

5.5.1.1. Port status

The unit internal Ethernet switch port status
Fig. 5.18: Menu Switch settings / Status / Port status
• Port name
Identification of the internal switch port. The switch ports are connected to an external port or to an
internal device (radio modem, management CPU).
○ Eth1 (port1) — The external port (with RJ45 interface) labeled "ETH1+POE".
○ Eth2 (port10) — The external port (with SFP interface) labeled "ETH2".
○ CPU (port0) — The internal port to management CPU.
○ Air (port9) — The internal port to radio modem, i.e. link to the peer unit.
• Link status
Ethernet link status can be
○ down — no link signal detected
○ up — link signal detected
• Speed / duplex
Ethernet link Speed and duplex.
○ Speed: — 0/100/1000 Mbps.
○ Duplex: — full/half
• SFP info
Information about the (optionally) inserted SFP module - see Section 1.3.2, "SFP slot (ETH2)" for
info about available SFP modules. Four situations may appear:
○ SFP OK — The SFP vendor string read out of SFP module. The vendor, model, connector (RJ45/LC)
and wavelength values are shown. Separate window with more detailed information can be opened
by clicking the "more..." link.
○ No SFP module — SFP module not inserted
○ read error — SFP info can not be read
○ no SFP option — n/a