Signal quality of the received signal. It is negative value of Mean Square Error (MSE, the inverse to
often used SNR - Signal to Noise Ratio).
• BER
Instantaneous bit error rate on link.
• Net bitrate
Instantaneous transmission capacity.
• Eth1, Eth2 in throughput
Instantaneous speed (20s average) of incoming user data on the user Ethernet port.
• Eth1, Eth2 out throughput
Instantaneous speed (20s average) of outgoing user data on the user Ethernet port.
• TX power
Instantaneous value of transmission power.

5.6.3.2. Viewer

Detailed graphical view of one or two selected values for the given interval. You can choose to view
data from Local or Peer or both.
Fig. 5.49: Menu Tools / History / Viewer
The values are saved in the following resolutions and history lengths:
Interval 1 hour - 3 hours, Resolution 1 minute, length of history 7 days
Interval 6 hours - 4 days, Resolution 15 minutes, length of history 30 days