5.4.4.2. Alarms Acknowledge

Fig. 5.16: Menu Link settings / Alarms / Acknowledge
Alarm acknowledgement allows the operator to confirm the system is set in alarm state. Only an active
alarm can be acknowledged. Multiple selections of active alarms (to acknowledge groups of alarms)
can be performed using Shift or Ctrl keys.
• Name
Alarm identification - The following alarms can appear:
Inside temperature, Voltage min, Voltage max, RSS, MSE, BER, Net bitrate, Air link, Eth1 link, Eth2
link, RF power, WiFi management
• State
There are three possible alarm states:
○ OK — No alarm (alarm is inactive) or alarm disabled.
○ Ack — Alarm is active and acknowledged.
○ Alarm — Alarm is active and is not acknowledged.
• From
Time stamp when the alarm occurred.
• To
Time stamp when the alarm expired (returned to normal conditions).
• Ack
Time stamp when the alarm was acknowledged.
Time stamp format: yyyy-MM-dd hh:mm:ss
• User
Name (login) of the user who acknowledged the alarm.
• Comment
© RACOM s.r.o. – RAy3 Microwave Link
Configuration
101