3.1. Service access

The RAy3 link is supplied with a default configuration of access parameters:
For Ethernet access through RJ45 or SFP ports:
• Unit L has the service IP address 192.168.169.169 and mask 255.255.255.0
• Unit U has the service IP address 192.168.169.170 and mask 255.255.255.0
For WiFi or Ethernet access via USB/WiFi or USB/ETH adapter:
• Both units have service IP address 172.17.17.17 and mask 255.255.255.0
For Ethernet access through RJ45 or SFP ports an IP address has to be set on your PC that is within
the mask, e.g. 192.168.169.180. For WiFi or USB/ETH access an IP address for laptop or mobile or
tablet is set automatically by DHCP (enabled by default).
Then open the HTTP or HTTPS configuration interface, e.g. https://192.168.169.169 or ht-
tp://172.17.17.17
Access is allowed over HTTP, HTTPS or SSH.
The default username and the password is "admin" (it is strongly recommended to change it).
See Configuration / Link settings / Service access / USB accessories chapter for detailed information.
The Antenna Alignment Web Tool can also be used for antenna direction alignment. It can be accessed
via a web browser utilizing IP addresses with „/tk" at the end (e.g. http://172.17.17.17/tk for WiFi or
USB/ETH adapter or http://192.168.169.169/tk or http://192.168.169.168/tk for ETH1/ETH2 ports).
When connection has been established, use the Service access menu to customize access parameters.
Default management IP addresses should be replaced with well-chosen operating addresses. Default
can lead to network problems later.
The menu contains parameters for the entire link, both for the Local and remote Peer units. If a connec-
tion has been established, both sets of parameters have been set. While working with an isolated unit,
only Local parameters are functional for the currently connected unit.
Note
If the link is OK and there are no parameters shown of the station Peer, it is necessary to click
on Refresh.
Follow the description of basic settings. Pictures in following sections show default factory settings for
L unit and RC info "rcinfo20_250_default:XXX". Default settings for unit U (for opposite side of the link)
would be adequately exchanged. Values for other RCinfo may be different as well (differences typically
refer to frequencies and Tx power as they are allowed by authorities for the actual band and a region).
After entering values on the screen always save the content by clicking on Apply.
© RACOM s.r.o. – RAy3 Microwave Link
Step-by-step Guide