Mounting The Unit In The Rack (C203-18) - Sony HXCU-FB70 Service Manual

With fiber connector kit hkc-lc02
Hide thumbs Also See for HXCU-FB70:
Table of Contents

Advertisement

6.
Set the unit in the rack while pressing the inner rail stopper into the outer rail as far as it will go.
Note
• This rack mounting work must be done by two or more workers so as not to hurt the worker s waist.
• Failure to tighten the rack angle screws may cause the unit to slide and fall from the rack, resulting in injury.
After the unit has been mounted, be sure to tighten all the screws.
• When setting and drawing the mounted unit, be careful not to catch your fingers by the rails.
• If balance is lost when mounting and removing the unit, it may fall, resulting in injury. Mount or remove the
unit carefully maintaining a stable posture.
Stopper
7.
After the unit has been set in the rack, secure the unit to the rack with four screws (PSW5 x 25).
1-7-2.

Mounting the Unit in the Rack (C203-18)

This unit is mounted in the rack by attaching the inner rails at the upper or lower part 1U of height 1.5U.
The rail attaching position varies depending on the unit mounting height in the rack.
Inner rail
1.5U
1.5U
HXCU-FB70
Rack
Stopper
Inner rail
PSW5 x 25
Other equipment
This unit
This unit
Other equipment
PSW5 x 25
When mounting this unit under other equipment,
install the inner rail at the upper part (1U) of the
unit.
Inner rail
When mounting this unit above other equipment,
install the inner rail at the lower part (1U) of the
unit.
1U
0.5U
0.5U
1U
1-18