Sony HXCU-FB70 Service Manual page 49

With fiber connector kit hkc-lc02
Hide thumbs Also See for HXCU-FB70:
Table of Contents

Advertisement

Cleaning of female connector
The optical contacts for female connector are in an unexposed state. In cleaning, it is necessary to be exposed by removing
the alignment sleeve in advance. Proceed as follows.
1.
Insert the alignment sleeve remover into the alignment sleeve in the straight line and turn it clockwise.
Alignment sleeve
2.
When the turn stops, pull out the remover in the straight line forcedly.
Note
The alignment sleeve can be removed/reinstalled with the sleeve itself attached to the tip of the remover. Great care
should be taken so as not to lose or damage the alignment sleeve.
Alignment sleeve: Sony Part No. : 9-980-074-01
Alignment sleeve
3.
Clean the tip of the white optical contacts with a cotton swab moistened with alcohol.
Optical contacts (white)
4.
Insert the remover with the alignment sleeve attached to its tip, and push it until it clicks.
5.
Rotate the remover counterclockwise to install the alignment sleeve, and extract the remover.
Cleaning of connector
Clean the tip of the white optical contacts with a cotton swab moistened with alcohol.
Optical contact
(white)
HXCU-FB70
Alignment sleeve remover