CENTER CONTROL PANEL PACK
CCP-9000-C
MKS-9011
MKS-9012
MKS-8011
MKS-8031TB
MKS-8032
MKS-8033
MKS-8035
MKS-8041
MKS-8075
SWC-5002
SWC-5005
SWC-5010
INSTALLATION MANUAL
1st Edition (Revised 1)

Advertisement

Table of Contents
loading

Summary of Contents for Sony CCP-9000-C

  • Page 1 CENTER CONTROL PANEL PACK CCP-9000-C MKS-9011 MKS-9012 MKS-8011 MKS-8031TB MKS-8032 MKS-8033 MKS-8035 MKS-8041 MKS-8075 SWC-5002 SWC-5005 SWC-5010 INSTALLATION MANUAL 1st Edition (Revised 1)
  • Page 2 ! WARNING This manual is intended for qualified service personnel only. To reduce the risk of electric shock, fire or injury, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. Refer all servicing to qualified service personnel.
  • Page 3 Attention-when the product is installed in Rack: 1. Prevention against overloading of branch circuit When this product is installed in a rack and is supplied power from an outlet on the rack, please make sure that the rack does not overload the supply circuit.
  • Page 5: Table Of Contents

    Table of Contents Manual Structure Purpose of this manual ....................3 Related manuals ......................3 Contents ........................4 1. Installation 1-1. Operating Environment (Common) ............1-1 1-2. Power Supply ....................1-1 1-3. Installation Space ..................1-2 1-3-1. External Dimensions ..............1-2 1-3-2.
  • Page 7: Manual Structure

    This manual describes the overview, system connection example and specifica- tions of options of CCP-9000-C..User’s Guide (Volume 1, Volume 2) (Supplied with CCP-9000-C) This manual describes the application and operation of CCP-9000-C..System Setup Manual (Available on request)
  • Page 8: Contents

    Contents This manual is organized by following section. Section 1 Installation This section describes the operating environment, power supply, installation space, installation of option, rack mounting, connectors, input and output signals of connectors, checking upon completion of installation, system configuration, and setup.
  • Page 9: Installation

    Section 1 Installation 1-1. Operating Environment (Common) As the inrush current at turn-on is a maximum 20 A (at 100 V)/60 A (at 230 V), the capacity of the AC power +5 dC to +40 dC Operating guaranteed temperature : source must be commensurate with this load.
  • Page 10: Installation Space

    1-3. Installation Space 1-3. Installation Space 1-3-1. External Dimensions Center controll panel MKS-9012/Menu panel MKS-8011 MKS-8011 MKS-9012 140.9 101.8 478.3 197.7 Unit : mm CCP-9000...
  • Page 11 1-3. Installation Space Center controll panel MKS-9011 140.9 101.8 478.3 197.7 Unit : mm CCP-9000...
  • Page 12 1-3. Installation Space Extension adaptor MKS-8075 Unit : mm CCP-9000...
  • Page 13: Installation Space

    1-3. Installation Space 1-3-2. Installation Space When the controll panel is recessed into a control console or similar, make holes as shown below into the control console with the following dimensions. 140 or more 2-ø3 hole with 3 or more in depth 6-M5 Model name Serial No.
  • Page 14: Installing The Control Panel

    1-4. Installing the Control Panel 1-4. Installing the Control Panel 3. While lifting up the control panel with one person, and holding it with another person, and then install the 1-4-1. Installing into the Control Console control panel into the control console. 4.
  • Page 15: Installing The Side Caps (L) And (R)

    1-4. Installing the Control Panel 1-4-2. Installing the Side Caps (L) and (R) 4. Install the three side caps (L) and (R) each on both sides by tightening the twelve screws. The width of the MKS-9011/9012 can be made below into 5.
  • Page 16: Installing The Menu Panel

    . Screws (B3 x 5) : 4 pcs from the factory. . EL table assemblies : 2 pcs (Sony Part No. : X-3167-779-1) Model name MKS-9011 1-M/E CONTROL PANEL 1. Open the screw holes (M4) as shown in the illustration...
  • Page 17: Installation To Mks-8075 (Extension Adaptor)

    1-6. Installation of Options 1-6-1. Installation to MKS-8075 (Extension 5. Install the module cover. Adaptor) Installation of the MKS-8031TB requires installation of the track ball after the module is installed in steps 1 Be sure to disconnect the power cord before starting to to 5.
  • Page 18: How To Connect The Mks-8075

    1-6. Installation of Options 1-6-2. How to Connect the MKS-8075 Connecting procedure 1. Remove the module cover. Remove the screws (BV3 x 10) fixing the caps (L) and (R), and remove the caps Structure of MKS-8075 (Extension adaptor) Adaptor case : in the direction of the arrow.
  • Page 19 1-6. Installation of Options When the Vertical connection is selected (3) Fix the bottom plate of the adaptor cases at the loca- (1) Connect the adaptor cases together. tions shown in the illustration using the 4 connecting (Be careful of the direction of the adaptor cases. See the screws (BV3 x 10) and 2 of the connecting plates B instruction given on the bottom of the adaptor case.) for every 2 adaptor cases.
  • Page 20 1-6. Installation of Options 7. For connection methods (A) and (B) (Refer to Fig. 2 (on page 1-13.)), install the caps (L) and (R), and the module cover in the direction of the arrow. Module covers BV3 x 10 Cap (L) Cap (R) BV3 x 10 For connection method (C) (Refer to Fig.
  • Page 21 1-6. Installation of Options Fig. 2 : Side panel installation methods FRONT FRONT Left side Connecting plate C FRONT FRONT Right side : Connecting plate screw fixing position : Side plate screw fixing position Connection method (A) FRONT FRONT Left side Connecting plate C FRONT FRONT...
  • Page 22: How To Connect The Cables

    Tools required . Screws (RK5 x 16) for rack mounting . Ornamental washers for rack mount (Sony part No.: 2-297-913-01) When 2 adaptors are connected : Each 4 pcs When 4 adaptors are connected : Each 8 pcs EXT PANEL 1.
  • Page 23 1-6. Installation of Options 2. Rack mounting procedures Install the adaptor into the rack using rack mounting screws (RK5 x 16) and ornamental washers as shown in the illustration. (The illustration below shows the configuration when 4 adaptors are installed.) RK5 x 16 Ornamental washer...
  • Page 24: Matching Connectors And Cables

    Matching connector and cable Name Sony part No. MKS-9011/9012 EXT PANEL D-sub 50-pin, Female Use the dedicated cable MENU PANEL specified by Sony Corp. D-sub 25-pin, Female D-sub 25-pin, Male Connector 25-pin, Male 1-566-356-11 Junction Shell 25-pin 1-563-377-11 EXT DISPLAY...
  • Page 25: Input/Output Signals Of Connectors

    1-8. Input/Output Signals of Connectors 1-8. Input/Output Signals of Connectors Pin No. Signal Name Function GPI OUT 6 General-purpose open collector Input and output signals of the connectors on the rear panel output (B) (*2) GPI OUT 8 are as follows. GPI OUT COM Ground for open collector output CTR/DATA/PERIPH : 100BASE-TX, RJ-45 (8-pin) Ground...
  • Page 26 1-8. Input/Output Signals of Connectors EDITOR PANEL : RS-422A (D-sub 9-pin, Female) EXT DISPLAY : (High-density D-sub 15-pin, analog (*3) <CONTROLLER> RGB, Female) to External Display EXT VIEW _ EXT VIEW _ Pin No. Signal Name Function Pin No. Signal Name Function Frame ground Video Red...
  • Page 27: Setting Of On-Board Switches And Function Of Leds

    1-9. Setting of On-board Switches and Function of LEDs 1-9. Setting of On-board Switches and Function of LEDs The number shown in the parentheses ( ) indicated the address on the circuit board. 1. CA-52 board ND610 D610 D640 D611 ND611 D641 D612...
  • Page 28 1-9. Setting of On-board Switches and Function of LEDs <LED> D610 (A-2) : PERIPH CPU status LED D250 (A-4) : LAN status LED PERIPH terminal communication IC status indication. LAN status indication. Used only for production in the assembly factory. Flashes while communication with MENU CPU.
  • Page 29 1-9. Setting of On-board Switches and Function of LEDs ND611 (B-2) : COM1 CPU status LED S902 (A-5) : Group ID setting switch for LAN PERIPH LAN control IC status indication. Sets the ID of the network group. Used to set the group ID for the CTRL, PERIPH and ND900 (B-4) : MAIN CPU status LED DATA terminals.
  • Page 30 1-9. Setting of On-board Switches and Function of LEDs D19 (green) (A-4) : CORE status LED <Switch on the CPU DK module> (COM0) (COM1) SW1 (D-5) : RESET switch Indicates the status of the VCC (CORE) power that is supplied to the CPU-DR module. Pressing this switch resets the CPU-DK module.
  • Page 31 1-9. Setting of On-board Switches and Function of LEDs 2. IF-897 board CN12 D101 A side/Component side <LED> D101 (green) (G-3) : IDE Flashes and lit while the hard disk is being accessed. <Connector> CN12 (H-3) : CF The Compact Flash interface that is used to control the menu screen.
  • Page 32 1-9. Setting of On-board Switches and Function of LEDs 3. PS-639 board E201 TP201 E301 TP101 TP301 D204 E101 D104 D304 A side/Component side <LED> <TEST terminal> D104 (green) (A-1) : + + + + + 5 V E1 (A-1) : GND terminal Indicates the status of the +5 V power that is supplied to Use this terminal as the ground point for measuring TP1 each board.
  • Page 33 1-9. Setting of On-board Switches and Function of LEDs 4. MAGIC-765 board JP16 JP17 JP18 JP19 JP10 JP20 JP21 JP22 JP14 JP15 JP23 JP24 JP5 JP6 JP13 A side/Component side Use the system with the default setup when shipped from the factory as stated below. Jumper Factory setting Setup contents...
  • Page 34: System Connection

    However, a single Ethernet switch can be used for connecting each LAN. For information about Ethernet switches that can be used in an MVS system, contact your local Sony Sales Office/Service Center. For detailed information about setting up the Ethernet switch, refer to the documentation supplied with the switch.
  • Page 35: Connecting The Center Control Panel

    1-10. System Connection 1-10-2. Connecting the Center Control Panel Connect the center control panel such as MKS-9011/9012, MKS-8011 and others referring to the follow- ing connection example. Connection example Extension Adaptor MKS-8075 (Max.10 m) SCU OUT SCU IN (Max.10 m) EXT PANEL SCU OUT SCU IN...
  • Page 37: Service Overview

    Section 2 Service Overview 2-1. Troubleshooting 2-1-1. Center Control Panel MKS-9011/9012 2-1-2. Menu Panel MKS-8011 The main power cannot be turned on. Nothing is displayed on the menu monitor screen (Indicator does not light green.) Flow 1 Flow 3 The main power of the MKS-9011/ Nothing is displayed on the menu 9012 cannot be turned on.
  • Page 38: Periodic Inspection And Maintenance

    1. Fan Cleaning the track ball every month is recommended. The inside of the CCP-9000-C is cooled by a fan on the rear. (1) Rotate the ball cover counterclockwise and release the If dust has accumulated in the intake of the fan, air is lock.
  • Page 39 The material contained in this manual consists of information that is the property of Sony Corporation. Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation.