Emerson Rosemount 2088 Reference Manual page 98

Pressure transmitter with hart revision 5 and 7 selectable protocol
Hide thumbs Also See for Rosemount 2088:
Table of Contents

Advertisement

Reference Manual
00809-0100-4108, Rev BA
Japanese certifications
E4
Brazil certifications
I2
E2
China certifications
I3
Product Certifications
TIIS Flameproof
Ex d IIC T6 (T
= 85 °C)
a
Certificate
Description
TC15874
2088 with Alloy C-276 wetted parts (with display)
TC15873
2088 with SST wetted parts (with display)
TC15872
2088 with Alloy C-276 wetted parts (no display)
TC15871
2088 with SST wetted parts (no display)
INMETRO Intrinsic Safety
Certificate: UL-BR 13.0246X
Markings: Ex ia IIC T5/T4 Ga
T5 (-55 °C  T
 +40 °C); T4 (-55 °C T
a
Special Conditions for Safe Use (X):
1. When fitted with a transient suppression terminal block, the model 2088 is incapable
of passing the 500 V isolation test. This must be taken into account during installation.
2. The enclosure may be made of aluminum alloy and given a protective polyurethane
paint finish; however, care should be taken to protect it from impact or abrasion if
located in a zone 0 environment.
INMETRO Flameproof (2088 Series only)
Certificate: CEPEL 97.0076
Markings: Ex d IIC T6/T5 Gb
T6 (-20 °C  T
 +40 °C); T5 (-20 °C  T
a
China Intrinsic Safety
Certificate: GYJ111063X (2088 Series); GYJ111065X (2090 Series)
Standards Used: GB3836.1-2000, GB3836.4-2000
Markings: Ex ia IIC T4/T5
T4 (-55 °C  T
 +70 °C);T5 (-55 °C  T
a
Table B-3. Input parameters
U
= 30 V
i
I
= 200 mA
i
P
= 0.9 W
i
C
= 0.012 μF
i
Appendix B: Product Certifications
 +70 °C)
a
 +60 °C)
a
 +40 °C)
a
March 2014
89

Advertisement

Table of Contents
loading

This manual is also suitable for:

G1s22a1b4e5q4p0021